Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults. Issue 5 (20th November 2020)
- Record Type:
- Journal Article
- Title:
- Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults. Issue 5 (20th November 2020)
- Main Title:
- Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults
- Authors:
- Duda, Jessica M.
Moser, Amelia D.
Zuo, Chun S.
Du, Fei
Chen, Xi
Perlo, Sarah
Richards, Christine E.
Nascimento, Nara
Ironside, Maria
Crowley, David J.
Holsen, Laura M.
Misra, Madhusmita
Hudson, James I.
Goldstein, Jill M.
Pizzagalli, Diego A. - Abstract:
- Abstract : Purpose: Gamma‐aminobutyric acid (GABA) abnormalities have been implicated in a range of neuropsychiatric disorders. Despite substantial interest in probing GABA in vivo, human imaging studies relying on magnetic resonance spectroscopy (MRS) have generally been hindered by technical challenges, including GABA's relatively low concentration and spectral overlap with other metabolites. Although past studies have shown moderate‐to‐strong test‐retest repeatability and reliability of GABA within certain brain regions, many of these studies have been limited by small sample sizes. Methods: GABA+ (macromolecular‐contaminated) test‐retest reliability and repeatability were assessed via a Meshcher‐Garwood point resolved spectroscopy (MEGA‐PRESS) MRS sequence in the rostral anterior cingulate cortex (rACC; n = 21) and dorsolateral prefrontal cortex (dlPFC; n = 20) in healthy young adults. Data were collected on a 3T scanner (Siemens Prisma, Siemens Healthcare, Erlangen, Germany) and GABA+ results were reported in reference to both total creatine (GABA+/tCr) and water (GABA+/water). Results: Results showed strong test‐retest repeatability (mean GABA+/tCr coefficient of variation [CV] = 4.6%; mean GABA+/water CV = 4.0%) and reliability (GABA+/tCr intraclass correlation coefficient [ICC] = 0.77; GABA+/water ICC = 0.87) in the dlPFC. The rACC showed acceptable (but comparatively lower) repeatability (mean GABA+/tCr CV = 8.0%; mean GABA+/water CV = 7.5%), yet low‐moderateAbstract : Purpose: Gamma‐aminobutyric acid (GABA) abnormalities have been implicated in a range of neuropsychiatric disorders. Despite substantial interest in probing GABA in vivo, human imaging studies relying on magnetic resonance spectroscopy (MRS) have generally been hindered by technical challenges, including GABA's relatively low concentration and spectral overlap with other metabolites. Although past studies have shown moderate‐to‐strong test‐retest repeatability and reliability of GABA within certain brain regions, many of these studies have been limited by small sample sizes. Methods: GABA+ (macromolecular‐contaminated) test‐retest reliability and repeatability were assessed via a Meshcher‐Garwood point resolved spectroscopy (MEGA‐PRESS) MRS sequence in the rostral anterior cingulate cortex (rACC; n = 21) and dorsolateral prefrontal cortex (dlPFC; n = 20) in healthy young adults. Data were collected on a 3T scanner (Siemens Prisma, Siemens Healthcare, Erlangen, Germany) and GABA+ results were reported in reference to both total creatine (GABA+/tCr) and water (GABA+/water). Results: Results showed strong test‐retest repeatability (mean GABA+/tCr coefficient of variation [CV] = 4.6%; mean GABA+/water CV = 4.0%) and reliability (GABA+/tCr intraclass correlation coefficient [ICC] = 0.77; GABA+/water ICC = 0.87) in the dlPFC. The rACC showed acceptable (but comparatively lower) repeatability (mean GABA+/tCr CV = 8.0%; mean GABA+/water CV = 7.5%), yet low‐moderate reliability (GABA+/tCr ICC = 0.40; GABA+/water ICC = 0.44). Conclusion: The present study found excellent GABA+ MRS repeatability and reliability in the dlPFC. The rACC showed inferior results, possibly because of a combination of shimming impedance and measurement error. These data suggest that MEGA‐PRESS can be utilized to reliably distinguish participants based on dlPFC GABA+ levels, whereas the mixed results in the rACC merit further investigation. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 5(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 5(2021)
- Issue Display:
- Volume 85, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2021-0085-0005-0000
- Page Start:
- 2359
- Page End:
- 2369
- Publication Date:
- 2020-11-20
- Subjects:
- anterior cingulate -- dorsolateral prefrontal cortex -- gamma‐aminobutyric acid -- LCModel -- MEGA‐PRESS -- magnetic resonance spectroscopy
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28587 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21832.xml