Accelerated aortic 4D flow MRI with wave‐CAIPI. Issue 5 (24th November 2020)
- Record Type:
- Journal Article
- Title:
- Accelerated aortic 4D flow MRI with wave‐CAIPI. Issue 5 (24th November 2020)
- Main Title:
- Accelerated aortic 4D flow MRI with wave‐CAIPI
- Authors:
- Richter, Julian A. J.
Wech, Tobias
Weng, Andreas M.
Stich, Manuel
Jin, Ning
Kosmala, Aleksander
Bley, Thorsten A.
Köstler, Herbert - Abstract:
- Abstract : Purpose: The aim of this study was to investigate the acceleration potential of wave‐CAIPI (controlled aliasing in parallel imaging) for 4D flow MRI, provided that image quality and precision of flow parameters are maintained. Methods: The 4D flow MRIs with acceleration factor R = 2 were performed on 10 healthy volunteers, using both wave‐CAIPI and standard Cartesian/2D‐CAIPI sampling for reference. In addition, 1 patient with known aortic valve stenosis was examined. The flow rate ( Q ), net flow ( Q net ), peak velocity v max, and net average through‐plane velocity ( v ¯ ⊥ ) were calculated in eight analysis planes in the ascending and descending aorta. The acquisitions were retrospectively undersampled ( R = 6), and deviations of flow parameters and hemodynamic flow patterns were evaluated. Results: Flow parameters measured with an undersampled wave‐CAIPI trajectory showed considerably smaller deviations to the references than the 2D‐CAIPI images. For v max, the mean absolute differences were 6.02 ± 2.08 cm/s versus 14.36 ± 5.68 cm/s; for Q net, the mean absolute differences were 3.67 ± 1.40 ml versus 5.87 ± 1.91 ml for wave‐CAIPI versus 2D‐CAIPI, respectively. Noise calculations indicate that the 2D‐CAIPI sampling exhibits a 43 ± 38 % higher average noise level than the wave‐CAIPI technique. Qualitative discrepancies in hemodynamic flow patterns, visualized through streamlines, particle traces and flow velocity vectors, could be reduced by using theAbstract : Purpose: The aim of this study was to investigate the acceleration potential of wave‐CAIPI (controlled aliasing in parallel imaging) for 4D flow MRI, provided that image quality and precision of flow parameters are maintained. Methods: The 4D flow MRIs with acceleration factor R = 2 were performed on 10 healthy volunteers, using both wave‐CAIPI and standard Cartesian/2D‐CAIPI sampling for reference. In addition, 1 patient with known aortic valve stenosis was examined. The flow rate ( Q ), net flow ( Q net ), peak velocity v max, and net average through‐plane velocity ( v ¯ ⊥ ) were calculated in eight analysis planes in the ascending and descending aorta. The acquisitions were retrospectively undersampled ( R = 6), and deviations of flow parameters and hemodynamic flow patterns were evaluated. Results: Flow parameters measured with an undersampled wave‐CAIPI trajectory showed considerably smaller deviations to the references than the 2D‐CAIPI images. For v max, the mean absolute differences were 6.02 ± 2.08 cm/s versus 14.36 ± 5.68 cm/s; for Q net, the mean absolute differences were 3.67 ± 1.40 ml versus 5.87 ± 1.91 ml for wave‐CAIPI versus 2D‐CAIPI, respectively. Noise calculations indicate that the 2D‐CAIPI sampling exhibits a 43 ± 38 % higher average noise level than the wave‐CAIPI technique. Qualitative discrepancies in hemodynamic flow patterns, visualized through streamlines, particle traces and flow velocity vectors, could be reduced by using the undersampled wave‐CAIPI trajectory. Conclusion: Use of wave‐CAIPI instead of 2D‐CAIPI sampling in retrospectively 6‐fold accelerated 4D flow MRI enhances the precision of flow parameters. The acquisition time of 4D flow measurements could be reduced by a factor of 3, with minimal differences in flow parameters. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 5(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 5(2021)
- Issue Display:
- Volume 85, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2021-0085-0005-0000
- Page Start:
- 2595
- Page End:
- 2607
- Publication Date:
- 2020-11-24
- Subjects:
- 4D flow -- aorta -- phase contrast -- wave‐CAIPI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28605 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21832.xml