Assessing initial plan check efficacy using TG 275 failure modes and incident reporting. Issue 6 (10th May 2022)
- Record Type:
- Journal Article
- Title:
- Assessing initial plan check efficacy using TG 275 failure modes and incident reporting. Issue 6 (10th May 2022)
- Main Title:
- Assessing initial plan check efficacy using TG 275 failure modes and incident reporting
- Authors:
- Riegel, Adam C.
Polvorosa, Cynthia
Sharma, Anurag
Baker, Jameson
Ge, William
Lauritano, Joseph
Calugaru, Emel
Chang, Jenghwa
Antone, Jeffrey
Oliveira, Angela
Buckenberger, Walkiria
Chen, William
Cao, Yijian
Kapur, Ajay
Potters, Louis - Abstract:
- Abstract: Plan checks are important components of a robust quality assurance (QA) program. Recently, the American Association of Physicists in Medicine (AAPM) published two reports concerning plan and chart checking, Task Group (TG) 275 and Medical Physics Practice Guideline (MPPG) 11.A. The purpose of the current study was to crosswalk initial plan check failure modes revealed in TG 275 against our institutional QA program and local incident reporting data. Ten physicists reviewed 46 high‐risk failure modes reported in Table S1.A.i of the TG 275 report. The committee identified steps in our planning process which sufficiently checked each failure mode. Failure modes that were not covered were noted for follow‐up. A multidisciplinary committee reviewed the narratives of 1599 locally‐reported incidents in our Radiation Oncology Incident Learning System (ROILS) database and categorized each into the high‐risk TG 275 failure modes. We found that over half of the 46 high‐risk failure modes, six of which were top‐ten failure modes, were covered in part by daily contouring peer‐review rounds, upstream of the traditional initial plan check. Five failure modes were not adequately covered, three of which concerned pregnancy, pacemakers, and prior dose. Of the 1599 incidents analyzed, 710 were germane to the initial plan check, 23.4% of which concerned missing pregnancy attestations. Most, however, were caught prior to CT simulation (98.8%). Physics review and initial plan check wereAbstract: Plan checks are important components of a robust quality assurance (QA) program. Recently, the American Association of Physicists in Medicine (AAPM) published two reports concerning plan and chart checking, Task Group (TG) 275 and Medical Physics Practice Guideline (MPPG) 11.A. The purpose of the current study was to crosswalk initial plan check failure modes revealed in TG 275 against our institutional QA program and local incident reporting data. Ten physicists reviewed 46 high‐risk failure modes reported in Table S1.A.i of the TG 275 report. The committee identified steps in our planning process which sufficiently checked each failure mode. Failure modes that were not covered were noted for follow‐up. A multidisciplinary committee reviewed the narratives of 1599 locally‐reported incidents in our Radiation Oncology Incident Learning System (ROILS) database and categorized each into the high‐risk TG 275 failure modes. We found that over half of the 46 high‐risk failure modes, six of which were top‐ten failure modes, were covered in part by daily contouring peer‐review rounds, upstream of the traditional initial plan check. Five failure modes were not adequately covered, three of which concerned pregnancy, pacemakers, and prior dose. Of the 1599 incidents analyzed, 710 were germane to the initial plan check, 23.4% of which concerned missing pregnancy attestations. Most, however, were caught prior to CT simulation (98.8%). Physics review and initial plan check were the least efficacious checks, with error detection rates of 31.8% and 31.3%, respectively, for some failure modes. Our QA process that includes daily contouring rounds resulted in increased upstream error detection. This work has led to several initiatives in the department, including increased automation and enhancement of several policies and procedures. With TG 275 and MPPG 11.A as a guide, we strongly recommend that departments consider an internal chart checking policy and procedure review. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 6(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 6(2022)
- Issue Display:
- Volume 23, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 6
- Issue Sort Value:
- 2022-0023-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-05-10
- Subjects:
- Chart checking -- incident reporting -- patient safety -- quality management
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13640 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21812.xml