A rapid and quantitative detection method for plasma soluble growth stimulating gene protein 2 based on time resolved fluorescence immunochromatography. Issue 22 (24th May 2022)
- Record Type:
- Journal Article
- Title:
- A rapid and quantitative detection method for plasma soluble growth stimulating gene protein 2 based on time resolved fluorescence immunochromatography. Issue 22 (24th May 2022)
- Main Title:
- A rapid and quantitative detection method for plasma soluble growth stimulating gene protein 2 based on time resolved fluorescence immunochromatography
- Authors:
- Jing, Xiaoying
Hong, Shanchao
Zhang, Jian
Yang, Xue
Geng, Xianlong
Ye, Yan
Hu, Zhigang - Abstract:
- Abstract : Plasma soluble growth stimulating gene protein 2 (sST2) was rapidly detected through a novel time-resolved fluorescence immunochromatography analysis (TRF-ICA). Abstract : Background : plasma soluble growth stimulating gene protein 2 (sST2) is a new generation biomarker in heart failure (HF), which is an independent predictor of adverse outcomes of heart failure. Thus, the establishment of a rapid and sensitive method for detecting sST2 is urgently needed. Methods : lanthanide element Eu 3+ coated fluorescent nanometer microspheres (Eu 3+ @FMN) can be used as markers to label monoclonal mouse anti-human sST2 antibody ST-01 (ST-01-Eu 3+ @FMN). When the immune sandwich complex formed between the monoclonal mouse anti-human sST2 antibody ST-02 and ST-01-Eu 3+ @FMN on the test band with the appearance of target object sST2, we can detect the fluorescence intensity of Eu 3+ on the test band and the quality control band using a dry fluorescence analyzer. We calculated the T / C value ( T / C = fluorescence intensity of the test band/fluorescence intensity of the quality control band), fitted to the calibration curve, and measured the concentration value of sST2 in the corresponding sample. Results : the best reaction time was 15 min after condition exploration, and the optimal sample volume was 80 μL. The detection sensitivity of the scheme was 2.14 ng mL −1 . The calibration curve of the assay was y = 0.0113 x + 0.0033, and the linear range was 5–200 ng mL −1 . NoAbstract : Plasma soluble growth stimulating gene protein 2 (sST2) was rapidly detected through a novel time-resolved fluorescence immunochromatography analysis (TRF-ICA). Abstract : Background : plasma soluble growth stimulating gene protein 2 (sST2) is a new generation biomarker in heart failure (HF), which is an independent predictor of adverse outcomes of heart failure. Thus, the establishment of a rapid and sensitive method for detecting sST2 is urgently needed. Methods : lanthanide element Eu 3+ coated fluorescent nanometer microspheres (Eu 3+ @FMN) can be used as markers to label monoclonal mouse anti-human sST2 antibody ST-01 (ST-01-Eu 3+ @FMN). When the immune sandwich complex formed between the monoclonal mouse anti-human sST2 antibody ST-02 and ST-01-Eu 3+ @FMN on the test band with the appearance of target object sST2, we can detect the fluorescence intensity of Eu 3+ on the test band and the quality control band using a dry fluorescence analyzer. We calculated the T / C value ( T / C = fluorescence intensity of the test band/fluorescence intensity of the quality control band), fitted to the calibration curve, and measured the concentration value of sST2 in the corresponding sample. Results : the best reaction time was 15 min after condition exploration, and the optimal sample volume was 80 μL. The detection sensitivity of the scheme was 2.14 ng mL −1 . The calibration curve of the assay was y = 0.0113 x + 0.0033, and the linear range was 5–200 ng mL −1 . No cross reaction was found when the samples contained BNP, NT-proBNP, and galectin-3, indicating a good specificity. The precision was good with a relative deviation < 15%. The coefficient of variation of detection results of low-concentration samples and high-concentration samples was 4.20% and 3.30% respectively in the same batch of strip tests, so the intra-assay CV was set as <10%; when different batches of strips were used for testing, the coefficient of variation of detection results of low-concentration samples and high-concentration samples was 10.06% and 8.38% respectively, so the inter-assay CV was set as <15%. Stability test results showed that the relative deviation of test results at each time node was <15%, indicating good stability of the assay strips. The correlation coefficient between the ST-01-Eu 3+ @FMN based time-resolved fluorescence immunochromatography analysis and sST2 ELISA kit was 0.98. To confirm the usage of our proposed TRF-ICA for clinical samples, it was used to determine the concentration of sST2 in samples obtained from 34 patients with heart insufficiency, acute and chronic heart failure. As a result, we successfully detected a minimal concentration of 5.21 ng mL −1 and a maximum concentration of 184.26 ng mL −1 for sST2. Conclusion : this technique provides a rapid, simple and quantitative detection method for sST2 in clinics. It can help clinicians to predict the incidence of adverse events in patients with HF. … (more)
- Is Part Of:
- Analytical methods. Volume 14:Issue 22(2022)
- Journal:
- Analytical methods
- Issue:
- Volume 14:Issue 22(2022)
- Issue Display:
- Volume 14, Issue 22 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 22
- Issue Sort Value:
- 2022-0014-0022-0000
- Page Start:
- 2179
- Page End:
- 2187
- Publication Date:
- 2022-05-24
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2ay00120a ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21822.xml