Evaluation of intraoperative aphakic eye axial length measurements using swept-source OCT. Issue 6 (June 2022)
- Record Type:
- Journal Article
- Title:
- Evaluation of intraoperative aphakic eye axial length measurements using swept-source OCT. Issue 6 (June 2022)
- Main Title:
- Evaluation of intraoperative aphakic eye axial length measurements using swept-source OCT
- Authors:
- Hienert, Julius
Amir-Asgari, Sahand
Matz, Holger
Hirnschall, Nino
Findl, Oliver - Abstract:
- Abstract : Intra-OP, swept-source OCT technology of the phakic and aphakic eye allows axial eye length measurements in cases in which preoperative biometric measurements are not possible. Abstract : Purpose: To evaluate intraoperative aphakic eye axial length (AL) measurements using swept-source optical coherence tomography (SS-OCT). Setting: Hanusch Hospital, Vienna, Austria. Design: Prospective single-center study. Methods: Patients scheduled for cataract surgery were measured using SS-OCT (IOLMaster 700, Carl Zeiss Meditec AG) to assess the AL. Intraoperatively (intra-OP), SS-OCT measurements were performed with a prototype device (IOLMaster 700 connected to an OPMI Lumera 700 microscope, CZM) at the beginning of cataract surgery furthermore of the aphakic eye and 2 months after surgery. Results: 106 patients were included. Of the 59 eyes of 59 patients, the phakic median AL preoperatively and intra-OP was 23.61 mm ± 0.96 (standard deviation [SD]) and 23.51 mm ± 0.96 (SD), respectively. The absolute median difference was 0.028 ± 0.02 (SD) ( P = .049). Median phakic AL intra-OP vs 2 months postoperatively (post-OP) was 23.51 mm ± 0.97 (SD) vs 23.49 mm ± 0.95 (SD). The absolute median difference was 0.049 ± 0.04 (SD) ( P = .000). Median AL intra-OP aphakic vs 2 months post-OP pseudophakic was 23.42 mm ± 0.97 (SD) vs 23.42 mm ± 0.97 (SD), respectively. Absolute median difference was 0.038 ± 0.04 (SD) ( P = .379). Conclusions: Intra-OP, SS-OCT technology of the phakic andAbstract : Intra-OP, swept-source OCT technology of the phakic and aphakic eye allows axial eye length measurements in cases in which preoperative biometric measurements are not possible. Abstract : Purpose: To evaluate intraoperative aphakic eye axial length (AL) measurements using swept-source optical coherence tomography (SS-OCT). Setting: Hanusch Hospital, Vienna, Austria. Design: Prospective single-center study. Methods: Patients scheduled for cataract surgery were measured using SS-OCT (IOLMaster 700, Carl Zeiss Meditec AG) to assess the AL. Intraoperatively (intra-OP), SS-OCT measurements were performed with a prototype device (IOLMaster 700 connected to an OPMI Lumera 700 microscope, CZM) at the beginning of cataract surgery furthermore of the aphakic eye and 2 months after surgery. Results: 106 patients were included. Of the 59 eyes of 59 patients, the phakic median AL preoperatively and intra-OP was 23.61 mm ± 0.96 (standard deviation [SD]) and 23.51 mm ± 0.96 (SD), respectively. The absolute median difference was 0.028 ± 0.02 (SD) ( P = .049). Median phakic AL intra-OP vs 2 months postoperatively (post-OP) was 23.51 mm ± 0.97 (SD) vs 23.49 mm ± 0.95 (SD). The absolute median difference was 0.049 ± 0.04 (SD) ( P = .000). Median AL intra-OP aphakic vs 2 months post-OP pseudophakic was 23.42 mm ± 0.97 (SD) vs 23.42 mm ± 0.97 (SD), respectively. Absolute median difference was 0.038 ± 0.04 (SD) ( P = .379). Conclusions: Intra-OP, SS-OCT technology of the phakic and aphakic eye shows excellent comparability to preoperative and postoperative measurements. This technique allows AL measurements with high precision in cases in which preoperative biometric measurements are not possible. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 48:Issue 6(2022)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 48:Issue 6(2022)
- Issue Display:
- Volume 48, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 6
- Issue Sort Value:
- 2022-0048-0006-0000
- Page Start:
- 663
- Page End:
- 666
- Publication Date:
- 2022-06
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000812 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21806.xml