Ultrasound in osteoarthritis of the hand: a comparison to computed tomography and histology. (9th July 2021)
- Record Type:
- Journal Article
- Title:
- Ultrasound in osteoarthritis of the hand: a comparison to computed tomography and histology. (9th July 2021)
- Main Title:
- Ultrasound in osteoarthritis of the hand: a comparison to computed tomography and histology
- Authors:
- Husic, Rusmir
Finzel, Stephanie
Stradner, Martin H
Dreu, Manuel
Hofmeister, Alexander
Beham-Schmid, Christine
Graninger, Winfried B
Fessler, Johannes
Dejaco, Christian - Abstract:
- Abstract: Objective: To compare structural findings between US, micro-CT (µCT) and histology in people with OA of the hands. Methods: We analysed DIP and PIP joints of 31 fingers from 15 dissecting-room cadavers with OA of the hands. The occurrence of bone erosions and osteophytes were recorded by US, µCT and histology at 16 regions for each joint and compared for each method. Results: In total, US ( n = 558, 56.2% of 992 examined regions) and µCT ( n = 493, 49.7%) detected a higher frequency of osteophytes at PIP and DIP joints than histology ( n = 161, 23.4% of 689 histological examined regions; P = 0.01). We found a comparable number of erosions with each method [US, n = 52 (5.2%); µCT, n = 43 (4.3%); histology, n = 35 (5.2%)]. Both imaging techniques correlated moderately with each other regarding the detection of osteophytes ( r = 0.54, P = 0.002) and erosions ( r = 0.43, P = 0.017). Neither US nor µCT correlated with histology regarding erosions or osteophytes. With histology as the reference, US had a sensitivity of 80% and a specificity of 32% to detect osteophytes, whereas µCT had a sensitivity of 73% and a specificity of 27%. For erosions, sensitivities (US 10% and µCT 6%, respectively) were much lower. Microscopically, erosions contained fibrous myxoid tissue extending from subcortical cavities through the breach of cortical bone. Conclusions: The ability of US to identify osteophytes was comparable to that of µCT, yielding a good sensitivity whenAbstract: Objective: To compare structural findings between US, micro-CT (µCT) and histology in people with OA of the hands. Methods: We analysed DIP and PIP joints of 31 fingers from 15 dissecting-room cadavers with OA of the hands. The occurrence of bone erosions and osteophytes were recorded by US, µCT and histology at 16 regions for each joint and compared for each method. Results: In total, US ( n = 558, 56.2% of 992 examined regions) and µCT ( n = 493, 49.7%) detected a higher frequency of osteophytes at PIP and DIP joints than histology ( n = 161, 23.4% of 689 histological examined regions; P = 0.01). We found a comparable number of erosions with each method [US, n = 52 (5.2%); µCT, n = 43 (4.3%); histology, n = 35 (5.2%)]. Both imaging techniques correlated moderately with each other regarding the detection of osteophytes ( r = 0.54, P = 0.002) and erosions ( r = 0.43, P = 0.017). Neither US nor µCT correlated with histology regarding erosions or osteophytes. With histology as the reference, US had a sensitivity of 80% and a specificity of 32% to detect osteophytes, whereas µCT had a sensitivity of 73% and a specificity of 27%. For erosions, sensitivities (US 10% and µCT 6%, respectively) were much lower. Microscopically, erosions contained fibrous myxoid tissue extending from subcortical cavities through the breach of cortical bone. Conclusions: The ability of US to identify osteophytes was comparable to that of µCT, yielding a good sensitivity when histology was used as the gold standard. The sensitivity of US and µCT to detecting erosions was low compared with histology. … (more)
- Is Part Of:
- Rheumatology. Volume 61(2022)Supplement 1
- Journal:
- Rheumatology
- Issue:
- Volume 61(2022)Supplement 1
- Issue Display:
- Volume 61, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 61
- Issue:
- 1
- Issue Sort Value:
- 2022-0061-0001-0000
- Page Start:
- SI73
- Page End:
- SI80
- Publication Date:
- 2021-07-09
- Subjects:
- ultrasonography -- osteoarthritis of the hands -- bone erosions -- micro-computed tomography
Rheumatism -- Periodicals
Rheumatology -- Periodicals
616.723005 - Journal URLs:
- http://rheumatology.oupjournals.org ↗
http://rheumatology.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1093/rheumatology/keab526 ↗
- Languages:
- English
- ISSNs:
- 1462-0324
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7960.731900
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21798.xml