Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly. (July 2022)
- Record Type:
- Journal Article
- Title:
- Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly. (July 2022)
- Main Title:
- Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly
- Authors:
- Godoy, Michael
Gustafson, Jonathan A.
Hertzler, Justin S.
Bischoff, Jeffrey E.
Pourzal, Robin
Lundberg, Hannah J. - Abstract:
- Abstract: Total hip arthroplasty (THA) failure and the need for revision surgery can result from fretting-corrosion damage of the head-neck modular taper junctions. Prior work has shown that implant geometry, such as microgrooves, influences damage on retrieved implants. Microgroove deformation within the modular taper junction occurs when the female head taper meets the male stem taper during THA surgical procedure. The objective of this work was to validate microgroove deformation after head-neck THA assembly as calculated by finite element analysis (FEA). Four 28 mm CoCrMo head tapers and four Ti6Al4V stem tapers were scanned via white light interferometry. Heads were assembled onto stem tapers until 6kN reaction force was achieved, followed by head removal using a cut-off machine. The stem tapers were then rescanned and analyzed. Simultaneously, a 2D axisymmetric FEA model was developed and assembled per implant geometries and experimental data. For experiments and FEA, the mean change in microgroove height was 1.23 µm and 1.40 µm, respectively. The largest microgroove height change occurred on the proximal stem taper due to the conical angles of the head and stem tapers. FEA showed that the head-stem assembly induced high stresses and microgroove peaks flattening. 76–89% and 91–100% of the microgrooves in the experiments and FEA, respectively, showed height changes along the contact length of the stem taper. A validated FEA model of THA head-neck modular junctionAbstract: Total hip arthroplasty (THA) failure and the need for revision surgery can result from fretting-corrosion damage of the head-neck modular taper junctions. Prior work has shown that implant geometry, such as microgrooves, influences damage on retrieved implants. Microgroove deformation within the modular taper junction occurs when the female head taper meets the male stem taper during THA surgical procedure. The objective of this work was to validate microgroove deformation after head-neck THA assembly as calculated by finite element analysis (FEA). Four 28 mm CoCrMo head tapers and four Ti6Al4V stem tapers were scanned via white light interferometry. Heads were assembled onto stem tapers until 6kN reaction force was achieved, followed by head removal using a cut-off machine. The stem tapers were then rescanned and analyzed. Simultaneously, a 2D axisymmetric FEA model was developed and assembled per implant geometries and experimental data. For experiments and FEA, the mean change in microgroove height was 1.23 µm and 1.40 µm, respectively. The largest microgroove height change occurred on the proximal stem taper due to the conical angles of the head and stem tapers. FEA showed that the head-stem assembly induced high stresses and microgroove peaks flattening. 76–89% and 91–100% of the microgrooves in the experiments and FEA, respectively, showed height changes along the contact length of the stem taper. A validated FEA model of THA head-neck modular junction contact mechanics is essential to identifying implant geometries and surface topographies that can potentially minimize the risk of fretting and fretting-corrosion at modular junctions. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 140(2022)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 140(2022)
- Issue Display:
- Volume 140, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 140
- Issue:
- 2022
- Issue Sort Value:
- 2022-0140-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-07
- Subjects:
- Total hip arthroplasty -- Head-neck modularity -- Microgrooves -- FEA -- Surface topography
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2022.111172 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21797.xml