Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry. (April 2022)
- Record Type:
- Journal Article
- Title:
- Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry. (April 2022)
- Main Title:
- Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry
- Authors:
- Fiagan, Yawo A.C.
Bossuyt, Evy
Machiels, Melanie
Nevens, Daan
Billiet, Charlotte
Poortmans, Philip
Gevaert, Thierry
Verellen, Dirk - Abstract:
- Abstract: Background and purpose: Postoperative ultrahypofractionated radiation therapy (UHFRT) in 5 fractions (fx) for breast cancer patients is as effective and safe as conventionally hypofractionated RT (HFRT) in 15 fx, liberating time for higher-level daily online Image-Guided Radiation Therapy (IGRT) corrections. In this retrospective study, treatment uncertainties occurring in patients treated with 5fx (5fx-group) were evaluated using electronic portal imaging device (EPID)-based in-vivo dosimetry (EIVD) and compared with the results from patients treated with conventionally HFRT (15fx-group) to validate the new technique and to evaluate if the shorter treatment schedule could have a positive effect on the treatment uncertainties. Materials and methods: EPID-based integrated transit dose images were acquired for each treatment fraction in the 5fx-group (203 patients) and on the first 3 days of treatment and weekly thereafter in the 15fx-group (203 patients). A total of 1015 EIVD measurements in the 5fx-group and 1144 in the 15fx-group were acquired. Of the latter group, 755 had been treated with online IGRT correction (i.e., Online-IGRT 15fx-group). Results: In the 15fx-group 12.0% of fractions failed (FFs) compared to 3.8% in the 5fx-group and 6.9% in the online-IGRT 15fx-group. Causes for FFs in the 15fx-group compared with the 5fx-group were patient positioning (7.4% vs. 2.2%), technical issues (3.1% vs. 1.2%) and breast swelling (1.4% vs. 0.5%). In the online-IGRTAbstract: Background and purpose: Postoperative ultrahypofractionated radiation therapy (UHFRT) in 5 fractions (fx) for breast cancer patients is as effective and safe as conventionally hypofractionated RT (HFRT) in 15 fx, liberating time for higher-level daily online Image-Guided Radiation Therapy (IGRT) corrections. In this retrospective study, treatment uncertainties occurring in patients treated with 5fx (5fx-group) were evaluated using electronic portal imaging device (EPID)-based in-vivo dosimetry (EIVD) and compared with the results from patients treated with conventionally HFRT (15fx-group) to validate the new technique and to evaluate if the shorter treatment schedule could have a positive effect on the treatment uncertainties. Materials and methods: EPID-based integrated transit dose images were acquired for each treatment fraction in the 5fx-group (203 patients) and on the first 3 days of treatment and weekly thereafter in the 15fx-group (203 patients). A total of 1015 EIVD measurements in the 5fx-group and 1144 in the 15fx-group were acquired. Of the latter group, 755 had been treated with online IGRT correction (i.e., Online-IGRT 15fx-group). Results: In the 15fx-group 12.0% of fractions failed (FFs) compared to 3.8% in the 5fx-group and 6.9% in the online-IGRT 15fx-group. Causes for FFs in the 15fx-group compared with the 5fx-group were patient positioning (7.4% vs. 2.2%), technical issues (3.1% vs. 1.2%) and breast swelling (1.4% vs. 0.5%). In the online-IGRT 15fx-group, 2.5% were attributed to patient positioning, 3.8% to technical issues and 0.5% to breast swelling. Conclusions: EIVD demonstrated that UHFRT for breast cancer results in less FFs compared to standard HFRT. A large proportion of this decrease could be explained by using daily online IGRT. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 22(2022)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 22(2022)
- Issue Display:
- Volume 22, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 22
- Issue:
- 2022
- Issue Sort Value:
- 2022-0022-2022-0000
- Page Start:
- 85
- Page End:
- 90
- Publication Date:
- 2022-04
- Subjects:
- Automated treatment delivery verification -- In-vivo dosimetry -- Ultrahypofractionated radiation therapy -- Early breast cancer
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2022.05.003 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21799.xml