Diagnostic accuracy of an automated artificial intelligence derived right ventricular to left ventricular diameter ratio tool on CT pulmonary angiography to predict pulmonary hypertension at right heart catheterisation. Issue 7 (July 2022)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of an automated artificial intelligence derived right ventricular to left ventricular diameter ratio tool on CT pulmonary angiography to predict pulmonary hypertension at right heart catheterisation. Issue 7 (July 2022)
- Main Title:
- Diagnostic accuracy of an automated artificial intelligence derived right ventricular to left ventricular diameter ratio tool on CT pulmonary angiography to predict pulmonary hypertension at right heart catheterisation
- Authors:
- Charters, P.F.P.
Rossdale, J.
Brown, W.
Burnett, T.A.
Komber, H.M.E.I.
Thompson, C.
Robinson, G.
MacKenzie Ross, R.
Suntharalingam, J.
Rodrigues, J.C.L. - Abstract:
- Abstract : Aim: To determine the diagnostic accuracy of an automated artificial intelligence derived right ventricle/left ventricle diameter ratio (RV/LV) computed tomography pulmonary angiography (CTPA) analysis tool to detect pulmonary hypertension (PH) in patients with suspected PH referred to a specialist centre. Materials and methods: The present study was a retrospective analysis of a prospectively maintained database of 202 consecutive patients with suspected PH, who underwent CTPA within 12 months of right heart catheterisation (RHC). Automated ventricular segmentation and RV/LV calculation (Imbio LLC, Minneapolis, MN, USA) was undertaken on the CTPA images. PH diagnosis was made using the RHC reference standard. Results: The automated RV/LV correlated more strongly with RHC metrics than main pulmonary artery (MPA) diameter and MPA to ascending aorta diameter ratio (MPA/AA) measured manually (mean pulmonary arterial pressure [mPAP] r=0.535, R 2 = 0.287 p <0.001; pulmonary vascular resistance [PVR] r=0.607, R 2 = 0.369 p <0.001). In the derivation cohort ( n= 100), the area under the receiver-operating curve for automated RV/LV discriminating PH was 0.752 (95% confidence interval [CI] 0.677–0.827, p <0.001). Using an optimised Youden's Index of ≥1.12 classified from derivation, automated RV/LV ratio analysis was more sensitive for the detection of PH with higher positive predictive value (PPV) when compared with manual MPA and MPA/AA in the validation cohortAbstract : Aim: To determine the diagnostic accuracy of an automated artificial intelligence derived right ventricle/left ventricle diameter ratio (RV/LV) computed tomography pulmonary angiography (CTPA) analysis tool to detect pulmonary hypertension (PH) in patients with suspected PH referred to a specialist centre. Materials and methods: The present study was a retrospective analysis of a prospectively maintained database of 202 consecutive patients with suspected PH, who underwent CTPA within 12 months of right heart catheterisation (RHC). Automated ventricular segmentation and RV/LV calculation (Imbio LLC, Minneapolis, MN, USA) was undertaken on the CTPA images. PH diagnosis was made using the RHC reference standard. Results: The automated RV/LV correlated more strongly with RHC metrics than main pulmonary artery (MPA) diameter and MPA to ascending aorta diameter ratio (MPA/AA) measured manually (mean pulmonary arterial pressure [mPAP] r=0.535, R 2 = 0.287 p <0.001; pulmonary vascular resistance [PVR] r=0.607, R 2 = 0.369 p <0.001). In the derivation cohort ( n= 100), the area under the receiver-operating curve for automated RV/LV discriminating PH was 0.752 (95% confidence interval [CI] 0.677–0.827, p <0.001). Using an optimised Youden's Index of ≥1.12 classified from derivation, automated RV/LV ratio analysis was more sensitive for the detection of PH with higher positive predictive value (PPV) when compared with manual MPA and MPA/AA in the validation cohort (n=102). Automated RV/LV compromise (1.12) and specific (1.335) thresholds were strongly predictive of mortality (log-rank 7.401, p =0.007 and log-rank 16.075, p <0.001 respectively). Conclusion: In suspected PH, automated RV/LV diameter thresholds have high sensitivity for PH, outperform manual MPA and MPA/AA and can predict survival. Highlights: Automated RV/LV analysis is feasible in real-world suspected pulmonary hypertension. Automated RV/LV thresholds perform favorably compared with manual metrics on CT in PH. Automated RV/LV analysis can predict survival in patients with suspected PH. … (more)
- Is Part Of:
- Clinical radiology. Volume 77:Issue 7(2022)
- Journal:
- Clinical radiology
- Issue:
- Volume 77:Issue 7(2022)
- Issue Display:
- Volume 77, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 77
- Issue:
- 7
- Issue Sort Value:
- 2022-0077-0007-0000
- Page Start:
- e500
- Page End:
- e508
- Publication Date:
- 2022-07
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2022.03.009 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21790.xml