A NEW METHOD FOR ESTIMATING INCREASE IN RADIATION DOSE ASSOCIATED WITH IODINATED CONTRAST USE. Issue 5 (4th April 2022)
- Record Type:
- Journal Article
- Title:
- A NEW METHOD FOR ESTIMATING INCREASE IN RADIATION DOSE ASSOCIATED WITH IODINATED CONTRAST USE. Issue 5 (4th April 2022)
- Main Title:
- A NEW METHOD FOR ESTIMATING INCREASE IN RADIATION DOSE ASSOCIATED WITH IODINATED CONTRAST USE
- Authors:
- Wang, Qiang
Fu, Qiang
Pang, Cong - Abstract:
- Abstract: This work investigates the impact of iodinated contrast medium (ICM) on radiation dose in computed tomography (CT) scans using linear models established through a phantom study. Thermoluminescence dosemeters (TLDs) were calibrated using semi-conductor X-ray dosemeters. An electron density phantom, with a vial containing TLDs and different concentrations of iodinated blood, were scanned at different tube voltages. Irradiated TLD outputs were measured and absorbed dose to iodinated blood calculated. CT numbers (tissue attenuation as measured by Hounsfield units) were plotted against absorbed doses to obtain linear models. Data from 49 real patient scans were used to validate the linear models. At each X-ray energy, CT numbers were linearly correlated with the absorbed doses, that is with the increase of blood iodine concentration, the CT number increased and the absorbed dose increased accordingly. ICM can cause an increase of organ dose; the average dose increases were 31.8 ± 8.9% for thyroid, 37.1 ± 9.2% for cardiac muscle, 77.7 ± 14.0% for cardiac chamber, 7.1 ± 2.3% for breast, 26.1 ± 7.3% for liver, 39.8 ± 11.8% for spleen, 96.3 ± 12.2% for renal cortex and 82.4 ± 11.6% for medulla nephrica. ICM used in enhanced CT scan resulted in increased organ doses. Our models for estimating organ dose based on CT number were established by experiment and verified in clinical use.
- Is Part Of:
- Radiation protection dosimetry. Volume 198:Issue 5(2022)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 198:Issue 5(2022)
- Issue Display:
- Volume 198, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 198
- Issue:
- 5
- Issue Sort Value:
- 2022-0198-0005-0000
- Page Start:
- 281
- Page End:
- 289
- Publication Date:
- 2022-04-04
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncac026 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21795.xml