Specialized computational methods for denoising, B1 correction, and kinetic modeling in hyperpolarized 13C MR EPSI studies of liver tumors. Issue 5 (3rd July 2021)
- Record Type:
- Journal Article
- Title:
- Specialized computational methods for denoising, B1 correction, and kinetic modeling in hyperpolarized 13C MR EPSI studies of liver tumors. Issue 5 (3rd July 2021)
- Main Title:
- Specialized computational methods for denoising, B1 correction, and kinetic modeling in hyperpolarized 13C MR EPSI studies of liver tumors
- Authors:
- Lee, Philip M.
Chen, Hsin‐Yu
Gordon, Jeremy W.
Zhu, Zihan
Larson, Peder E.Z.
Dwork, Nicholas
Van Criekinge, Mark
Carvajal, Lucas
Ohliger, Michael A.
Wang, Zhen J.
Xu, Duan
Kurhanewicz, John
Bok, Robert A.
Aggarwal, Rahul
Munster, Pamela N.
Vigneron, Daniel B. - Abstract:
- Abstract : Purpose: To develop a novel post‐processing pipeline for hyperpolarized (HP) 13 C MRSI that integrates tensor denoising and B 1 + correction to measure pyruvate‐to‐lactate conversion rates (kPL ) in patients with liver tumors. Methods: Seven HP 13 C MR scans of progressing liver tumors were acquired using a custom 13 C surface transmit/receive coil and the echo‐planar spectroscopic imaging (EPSI) data analysis included B0 correction, tensor rank truncation, and zero‐ and first‐order phase corrections to recover metabolite signals that would otherwise be obscured by spectral noise as well as a correction for inhomogeneous transmit ( B 1 + ) using a B 1 + map aligned to the coil position for each patient scan. Processed HP data and corrected flip angles were analyzed with an inputless two‐site exchange model to calculate kPL . Results: Denoising averages SNR increases of pyruvate, lactate, and alanine were 37.4‐, 34.0‐, and 20.1‐fold, respectively, with lactate and alanine dynamics most noticeably recovered and better defined. In agreement with Monte Carlo simulations, over‐flipped regions underestimated kPL and under‐flipped regions overestimated kPL . B 1 + correction addressed this issue. Conclusion: The new HP 13 C EPSI post‐processing pipeline integrated tensor denoising and B 1 + correction to measure kPL in patients with liver tumors. These technical developments not only recovered metabolite signals in voxels that did not receive the prescribed flip angle,Abstract : Purpose: To develop a novel post‐processing pipeline for hyperpolarized (HP) 13 C MRSI that integrates tensor denoising and B 1 + correction to measure pyruvate‐to‐lactate conversion rates (kPL ) in patients with liver tumors. Methods: Seven HP 13 C MR scans of progressing liver tumors were acquired using a custom 13 C surface transmit/receive coil and the echo‐planar spectroscopic imaging (EPSI) data analysis included B0 correction, tensor rank truncation, and zero‐ and first‐order phase corrections to recover metabolite signals that would otherwise be obscured by spectral noise as well as a correction for inhomogeneous transmit ( B 1 + ) using a B 1 + map aligned to the coil position for each patient scan. Processed HP data and corrected flip angles were analyzed with an inputless two‐site exchange model to calculate kPL . Results: Denoising averages SNR increases of pyruvate, lactate, and alanine were 37.4‐, 34.0‐, and 20.1‐fold, respectively, with lactate and alanine dynamics most noticeably recovered and better defined. In agreement with Monte Carlo simulations, over‐flipped regions underestimated kPL and under‐flipped regions overestimated kPL . B 1 + correction addressed this issue. Conclusion: The new HP 13 C EPSI post‐processing pipeline integrated tensor denoising and B 1 + correction to measure kPL in patients with liver tumors. These technical developments not only recovered metabolite signals in voxels that did not receive the prescribed flip angle, but also increased the extent and accuracy of kPL estimations throughout the tumor and adjacent regions including normal‐appearing tissue and additional lesions. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 5(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 5(2021)
- Issue Display:
- Volume 86, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 5
- Issue Sort Value:
- 2021-0086-0005-0000
- Page Start:
- 2402
- Page End:
- 2411
- Publication Date:
- 2021-07-03
- Subjects:
- analysis -- B1 correction -- hyperpolarized 13C‐pyruvate MR
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28901 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21783.xml