Validation of the AGCU Expressmarker 20 + 20Y kit: A 6-dye multiplex assay for forensic application. (July 2022)
- Record Type:
- Journal Article
- Title:
- Validation of the AGCU Expressmarker 20 + 20Y kit: A 6-dye multiplex assay for forensic application. (July 2022)
- Main Title:
- Validation of the AGCU Expressmarker 20 + 20Y kit: A 6-dye multiplex assay for forensic application
- Authors:
- Wei, Xiaowen
Song, Feng
Wang, Xindi
Wang, Shuangshuang
Jiang, Lanrui
Zhang, Ke
Zhou, Yuxiang
Wang, Zefei
Liao, Miao
Zha, Lagabaiyila
Luo, Haibo - Abstract:
- Abstract: The AGCU Expressmarker 20 + 20Y Kit is a newly devised short tandem repeat (STR) multiplex system that simultaneously analyses a set of 19 autosomal STR loci, 20 Y chromosomal STR loci and the amelogenin locus with six-dye fluorescent labelling. Here, the AGCU Expressmarker 20 + 20Y system was validated following the guidelines published by the Scientific Working Group on DNA Analysis Methods (SWGDAM), including PCR-condition, sensitivity, mixtures, species specificity, models of inhibition, precision, stutter percentage, concordance, population genetic studies, performance on three kinds of degraded DNA and a type of casework samples. The results indicated that the kit had high sensitivity when there was a small amount of DNA (0.0625 ng), more than one male (minor: major=1:19), or a mixture of males and females (male: female=1:32), models of inhibition (250 μM hematin, 1500 ng/μL humic acid and more than 100 ng/μL tannic acid) and degraded samples. The kit showed high precision level with standard deviation of allele size no more than 0.0930. Furthermore, this system was also tested in 444 random male samples of Chinese Han and Hui population, showing its high discrimination capability in Han and Hui population. Meanwhile, the system was applicable to the case of the AMELY abnormality. In short, the kit was verified and proved to be a robust, reliable and suitable tool for human identification and casework samples. Highlights: Developmental validation followingAbstract: The AGCU Expressmarker 20 + 20Y Kit is a newly devised short tandem repeat (STR) multiplex system that simultaneously analyses a set of 19 autosomal STR loci, 20 Y chromosomal STR loci and the amelogenin locus with six-dye fluorescent labelling. Here, the AGCU Expressmarker 20 + 20Y system was validated following the guidelines published by the Scientific Working Group on DNA Analysis Methods (SWGDAM), including PCR-condition, sensitivity, mixtures, species specificity, models of inhibition, precision, stutter percentage, concordance, population genetic studies, performance on three kinds of degraded DNA and a type of casework samples. The results indicated that the kit had high sensitivity when there was a small amount of DNA (0.0625 ng), more than one male (minor: major=1:19), or a mixture of males and females (male: female=1:32), models of inhibition (250 μM hematin, 1500 ng/μL humic acid and more than 100 ng/μL tannic acid) and degraded samples. The kit showed high precision level with standard deviation of allele size no more than 0.0930. Furthermore, this system was also tested in 444 random male samples of Chinese Han and Hui population, showing its high discrimination capability in Han and Hui population. Meanwhile, the system was applicable to the case of the AMELY abnormality. In short, the kit was verified and proved to be a robust, reliable and suitable tool for human identification and casework samples. Highlights: Developmental validation following SWGDAM guidelines on the AGCU Expressmarker 20 + 20Y Kit. A 6-dye fluorescent analysis assay simultaneously amplifies 19 autosomal loci, 20 Y chromosomal-STR loci and a sex locus. 444 random male samples from Chinese Han and Hui populations showed high discrimination capability. The kit is applicable to the cases of the AMELY abnormality and meet the requirements of the Chinese national DNA database. … (more)
- Is Part Of:
- Forensic science international. Volume 336(2022)
- Journal:
- Forensic science international
- Issue:
- Volume 336(2022)
- Issue Display:
- Volume 336, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 336
- Issue:
- 2022
- Issue Sort Value:
- 2022-0336-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-07
- Subjects:
- Forensic science -- Validation -- Short tandem repeat (STR) -- AGCU Expressmarker 20 + 20Y Kit
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2022.111342 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21754.xml