Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate. (March 2022)
- Record Type:
- Journal Article
- Title:
- Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate. (March 2022)
- Main Title:
- Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate
- Authors:
- Giovannini, Giorgia
Cinelli, Paolo
Boesel, Luciano F.
Rossi, René M. - Abstract:
- Abstract: The concentration of glucose in the body's fluids is an important parameter that can indicate pathological conditions such as the progress of infected wounds. Several wearables and implantable detection approaches have been developed with high selectivity and sensitivity for glucose. However, all of them have drawbacks such as low stability, limited selectivity, and often require complex technology. In this work, we present a fluorescent-based cost-efficient imprinted hydrogel (MIH_GSH) capable of detecting glucose within 30 min. The imprinting approach allows us to improve the selectivity for glucose, overcoming the low specificity and limited binding efficiency at neutral pH of boronic acid-based detection mechanisms. The binding affinity determined for glucose-MIH_GSH was indeed 6-fold higher than the one determined for the non-imprinted hydrogel with a calculated imprinting factor of 1.7. The limit of detection of MIH_GSH for glucose in artificial wound exudate was calculated as 0.48 mM at pH 7.4 proving the suitability of the proposed approach to diagnose chronic wounds ( ca. 1 mM). MIH_GSH was compared with a commercial colorimetric assay for the quantification of glucose in wound exudate specimens collected from hospitalized patients. The results obtained with the two methods were statistically similar confirming the robustness of our approach. Importantly, whereas with the colorimetric assay sample preparation was required to limit the interference ofAbstract: The concentration of glucose in the body's fluids is an important parameter that can indicate pathological conditions such as the progress of infected wounds. Several wearables and implantable detection approaches have been developed with high selectivity and sensitivity for glucose. However, all of them have drawbacks such as low stability, limited selectivity, and often require complex technology. In this work, we present a fluorescent-based cost-efficient imprinted hydrogel (MIH_GSH) capable of detecting glucose within 30 min. The imprinting approach allows us to improve the selectivity for glucose, overcoming the low specificity and limited binding efficiency at neutral pH of boronic acid-based detection mechanisms. The binding affinity determined for glucose-MIH_GSH was indeed 6-fold higher than the one determined for the non-imprinted hydrogel with a calculated imprinting factor of 1.7. The limit of detection of MIH_GSH for glucose in artificial wound exudate was calculated as 0.48 mM at pH 7.4 proving the suitability of the proposed approach to diagnose chronic wounds ( ca. 1 mM). MIH_GSH was compared with a commercial colorimetric assay for the quantification of glucose in wound exudate specimens collected from hospitalized patients. The results obtained with the two methods were statistically similar confirming the robustness of our approach. Importantly, whereas with the colorimetric assay sample preparation was required to limit the interference of the sample background, the fluorescent signal of MIH_GSH was not affected even when used to measure glucose directly in bloody samples. The sensing mechanism here proposed can pave the way for the development of cost-efficient and wearable point-of-care tools capable of monitoring the glucose level in wound exudate enabling the quick assessment of chronic injuries. Graphical abstract: Image 1 Highlights: Highly sensitive and selective non-enzymatic approach to detect glucose in wound exudate. The fluorescent-based method ensured the detection of glucose in complex biological samples. The imprinting approach allowed overcoming the drawback of boronic acid-based methods. The cost-efficient approach is suitable for the development of point-of-care devices. … (more)
- Is Part Of:
- Materials today bio. Volume 14(2022)
- Journal:
- Materials today bio
- Issue:
- Volume 14(2022)
- Issue Display:
- Volume 14, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 2022
- Issue Sort Value:
- 2022-0014-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- Fluorescence -- Glucose detection -- Molecularly imprinted hydrogel -- Thioflavin -- Boronic acid -- Wound exudate
Materials science -- Periodicals
Biomedical engineering -- Periodicals
Biomedical materials -- Periodicals
620.1 - Journal URLs:
- https://www.sciencedirect.com/journal/materials-today-bio ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.mtbio.2022.100258 ↗
- Languages:
- English
- ISSNs:
- 2590-0064
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21754.xml