Analysis of diaphragm movements to specify geometric uncertainties of respiratory gating near end-exhalation for irradiation fields involving the liver dome. (June 2022)
- Record Type:
- Journal Article
- Title:
- Analysis of diaphragm movements to specify geometric uncertainties of respiratory gating near end-exhalation for irradiation fields involving the liver dome. (June 2022)
- Main Title:
- Analysis of diaphragm movements to specify geometric uncertainties of respiratory gating near end-exhalation for irradiation fields involving the liver dome
- Authors:
- Tony Liang, Hsiang-Kuang
Takei, Hideyuki
Tomita, Tetsuya
Terunuma, Toshiyuki
Isobe, Tomonori
Okumura, Toshiyuki
Sakae, Takeji
Sakurai, Hideyuki - Abstract:
- Highlights: For respiratory-gated radiotherapy near end-exhalation and irradiation fields involving the liver dome, components of geometric uncertainties originate from temporospatial diaphragm segment movements. The displacements in a caudal direction of the diaphragm in dorsal/medial segments are significantly larger than those in ventral/right segments. Personalized irradiating strategies, including inhalation phases of irradiation and beam angles of incidence, are required to reduce the temporospatial geometric uncertainties. Abstract: Background and Purpose: The technique of gating near end-exhalation is commonly adopted to reduce respiration-associated geometric uncertainties for particle beam therapy. However, for irradiation fields involving the liver dome, how diaphragm movements generating liver–lung interface change, alongside geometric uncertainties, remain unspecified. Methods and Materials: Patients receiving respiratory-gated computed tomography (RGCT) with four-dimensional computed tomography (4DCT) scans during simulation were retrospectively reviewed. Differences (Δ) between RGCT and 4DCT images, including diaphragm displacements and liver–lung interface changes, were investigated to specify geometric uncertainties during early inhalation phases. Craniocaudal displacements (Δy, in sagittal/coronal planes) of diaphragm segments (dorsal/ventral/right lateral/medial), liver area changes (ΔA, in axial planes), and liver extent changes in specific directions ofHighlights: For respiratory-gated radiotherapy near end-exhalation and irradiation fields involving the liver dome, components of geometric uncertainties originate from temporospatial diaphragm segment movements. The displacements in a caudal direction of the diaphragm in dorsal/medial segments are significantly larger than those in ventral/right segments. Personalized irradiating strategies, including inhalation phases of irradiation and beam angles of incidence, are required to reduce the temporospatial geometric uncertainties. Abstract: Background and Purpose: The technique of gating near end-exhalation is commonly adopted to reduce respiration-associated geometric uncertainties for particle beam therapy. However, for irradiation fields involving the liver dome, how diaphragm movements generating liver–lung interface change, alongside geometric uncertainties, remain unspecified. Methods and Materials: Patients receiving respiratory-gated computed tomography (RGCT) with four-dimensional computed tomography (4DCT) scans during simulation were retrospectively reviewed. Differences (Δ) between RGCT and 4DCT images, including diaphragm displacements and liver–lung interface changes, were investigated to specify geometric uncertainties during early inhalation phases. Craniocaudal displacements (Δy, in sagittal/coronal planes) of diaphragm segments (dorsal/ventral/right lateral/medial), liver area changes (ΔA, in axial planes), and liver extent changes in specific directions of incidence (Δr, in axial planes) were analyzed. Results: Altogether, 162 patients received simulating RGCT and 4DCT scans. In 22 of them, both images involved the liver dome. For most cases during early inhalation phases, the Δy values in the dorsal diaphragm were significantly greater than those in the ventral diaphragm ( p < 0.05), the ΔA values were significantly enlarged with inhalation progressing ( p < 0.05), and the Δr values in the dorsal direction were significantly larger than those in the ventral direction ( p < 0.05). These results suggested that the dorsal diaphragm moves earlier and more in a caudal direction than the ventral diaphragm during early inhalation phases. Conclusions: For respiratory-gated radiotherapy near end-exhalation and irradiation fields involving the liver dome, components of geometric uncertainties are temporospatial, including diaphragm segment movements, inhalation phases of irradiation, and beam angles of incidence. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 171(2022)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 171(2022)
- Issue Display:
- Volume 171, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 171
- Issue:
- 2022
- Issue Sort Value:
- 2022-0171-2022-0000
- Page Start:
- 146
- Page End:
- 154
- Publication Date:
- 2022-06
- Subjects:
- Respiratory gating -- Radiotherapy -- Geometric uncertainties -- Diaphragm movement -- Liver dome
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2022.04.018 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21750.xml