Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM10, and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial. (19th July 2021)
- Record Type:
- Journal Article
- Title:
- Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM10, and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial. (19th July 2021)
- Main Title:
- Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM10, and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial
- Authors:
- Riederer, Anne M.
Krenz, Jennifer E.
Tchong‐French, Maria I.
Torres, Elizabeth
Perez, Adriana
Younglove, Lisa R.
Jansen, Karen L.
Hardie, David C.
Farquhar, Stephanie A.
Sampson, Paul D.
Metwali, Nervana
Thorne, Peter S.
Karr, Catherine J. - Abstract:
- Abstract: We conducted a randomized trial of portable HEPA air cleaners in the homes of children age 6–12 years with asthma in the Yakima Valley, Washington. All families received asthma education while intervention families also received two HEPA cleaners (child's bedroom, living room). We collected 14‐day integrated samples of endotoxin in settled dust and PM10 and PM10‐2.5 in the air of the children's bedrooms at baseline and one‐year follow‐up, and used linear regression to compare follow‐up levels, adjusting for baseline. Seventy‐one families (36 HEPA, 35 control) completed the study. Baseline geometric mean (GSD) endotoxin loadings were 1565 (6.3) EU/m 2 and 2110 (4.9) EU/m 2, respectively, in HEPA vs. control homes while PM10 and PM10‐2.5 were 22.5 (1.9) μg/m 3 and 9.5 (2.9) μg/m 3, respectively, in HEPA homes, and 19.8 (1.8) μg/m 3 and 7.7 (2.0) μg/m 3, respectively, in control homes. At follow‐up, HEPA families had 46% lower (95% CI, 31%–57%) PM10 on average than control families, consistent with prior studies. In the best‐fit heterogeneous slopes model, HEPA families had 49% (95% CI, 6%–110%) and 89% lower (95% CI, 28%–177%) PM10‐2.5 at follow‐up, respectively, at 50th and 75th percentile baseline concentrations. Endotoxin loadings did not differ significantly at follow‐up (4% lower, HEPA homes; 95% CI, −87% to 50%).
- Is Part Of:
- Indoor air. Volume 31:Number 6(2021)
- Journal:
- Indoor air
- Issue:
- Volume 31:Number 6(2021)
- Issue Display:
- Volume 31, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 6
- Issue Sort Value:
- 2021-0031-0006-0000
- Page Start:
- 1926
- Page End:
- 1939
- Publication Date:
- 2021-07-19
- Subjects:
- asthma -- children -- coarse PM -- endotoxin -- HEPA cleaners
Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Ventilation -- Periodicals
613.5 - Journal URLs:
- http://www.blackwell-synergy.com/loi/ina ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ina.12858 ↗
- Languages:
- English
- ISSNs:
- 0905-6947
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4438.046530
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21729.xml