Vertical split fracture of the vertebral body following oblique lumbar interbody fusion: A case report. Issue 21 (27th May 2022)
- Record Type:
- Journal Article
- Title:
- Vertical split fracture of the vertebral body following oblique lumbar interbody fusion: A case report. Issue 21 (27th May 2022)
- Main Title:
- Vertical split fracture of the vertebral body following oblique lumbar interbody fusion
- Authors:
- Hong, Jong-Hwan
Han, Moon-Soo
Lee, Jung-Kil
Moon, Bong Ju - Editors:
- Saranathan., Maya
- Abstract:
- Abstract: Rationale: Oblique lumbar interbody fusion (OLIF) is an effective and safe surgical technique widely used for treating spondylolisthesis; however, its use is controversial because of several associated complications, including endplate injury. We report a rare vertebral body fracture following OLIF in a patient with poor bone quality. Patient concerns: A 72-year-old male patient visited our clinic for 2 years with lower back pain, leg radiating pain, and intermittent neurogenic claudication. Diagnoses: Lumbar magnetic resonance imaging revealed L4-5 stenosis. Intervention: We performed OLIF with percutaneous pedicle screw fixation and L4 subtotal decompressive laminectomy. We resected the anterior longitudinal ligament partially for anterior column release and inserted a huge cage to maximize segmental lordosis. No complications during and after the operation were observed. Further, the radiating pain and back pain improved, and the patient was discharged. Two weeks after the operation, the patient visited the outpatient department complaining of sudden recurred pain, which occurred while going to the bathroom. Radiography and computed tomography revealed a split fracture of the L5 body and an anterior cage displacement. In revision of OLIF, we removed the dislocated cage and filled the bone cement between the anterior longitudinal ligament and empty disc space. Further, we performed posterior lumbar interbody fusion L4-5, and the screw was extended to S1.Abstract: Rationale: Oblique lumbar interbody fusion (OLIF) is an effective and safe surgical technique widely used for treating spondylolisthesis; however, its use is controversial because of several associated complications, including endplate injury. We report a rare vertebral body fracture following OLIF in a patient with poor bone quality. Patient concerns: A 72-year-old male patient visited our clinic for 2 years with lower back pain, leg radiating pain, and intermittent neurogenic claudication. Diagnoses: Lumbar magnetic resonance imaging revealed L4-5 stenosis. Intervention: We performed OLIF with percutaneous pedicle screw fixation and L4 subtotal decompressive laminectomy. We resected the anterior longitudinal ligament partially for anterior column release and inserted a huge cage to maximize segmental lordosis. No complications during and after the operation were observed. Further, the radiating pain and back pain improved, and the patient was discharged. Two weeks after the operation, the patient visited the outpatient department complaining of sudden recurred pain, which occurred while going to the bathroom. Radiography and computed tomography revealed a split fracture of the L5 body and an anterior cage displacement. In revision of OLIF, we removed the dislocated cage and filled the bone cement between the anterior longitudinal ligament and empty disc space. Further, we performed posterior lumbar interbody fusion L4-5, and the screw was extended to S1. Outcomes: After the second surgery, back pain and radiating pain in the left leg improved, and he was discharged without complications. Lesson: In this case, owing to insufficient intervertebral space during L4-5 OLIF, a huge cage was used to achieve sufficient segmental lordosis after anterior column release, but a vertebral body coronal fracture occurred. In patients with poor bone quality and less flexibility, a huge cage and over-distraction could cause a vertebral fracture; hence, selecting an appropriate cage or considering a posterior approach is recommended. … (more)
- Is Part Of:
- Medicine. Volume 101:Issue 21(2022)
- Journal:
- Medicine
- Issue:
- Volume 101:Issue 21(2022)
- Issue Display:
- Volume 101, Issue 21 (2022)
- Year:
- 2022
- Volume:
- 101
- Issue:
- 21
- Issue Sort Value:
- 2022-0101-0021-0000
- Page Start:
- e29423
- Page End:
- Publication Date:
- 2022-05-27
- Subjects:
- anterior column release -- oblique lumbar interbody fusion -- osteoporosis -- vertebral fracture
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000029423 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21733.xml