Ratchet mechanism selectively causing idiopathic macrodislodgement of an active-fixation coronary sinus lead: a case report. Issue 6 (28th December 2020)
- Record Type:
- Journal Article
- Title:
- Ratchet mechanism selectively causing idiopathic macrodislodgement of an active-fixation coronary sinus lead: a case report. Issue 6 (28th December 2020)
- Main Title:
- Ratchet mechanism selectively causing idiopathic macrodislodgement of an active-fixation coronary sinus lead: a case report
- Authors:
- Golzio, Pier Giorgio
Bissolino, Arianna
Ceci, Raffaele
Frea, Simone - Editors:
- Linh, Ngo
Khan, Habib Rehman
Khan, Habib Rehman
Iliodromitis, Konstantinos
Constantinos, Bakogiannis
Mehta, Vishal Shahil - Abstract:
- Abstract: Background : 'Idiopathic' lead macrodislodgement may be due to Twiddler's syndrome depending on active twisting of pulse generator within subcutaneous pocket. All leads are involved, at any time from implantation, and frequently damaged. In the past few years, a reel syndrome was also observed: retraction of pacemaker leads into pocket without patient manipulation, owing to lead circling the generator. In other cases, a 'ratchet' mechanism has been postulated. Reel and ratchet mechanisms require loose anchoring, occur generally briefly after implantation, with non-damaged leads. We report the first case of an active-fixation coronary sinus lead selective macrodislodgement involving such ratchet mechanism. Case summary : A 65-year-old man underwent biventricular defibrillator device implantation, with active-fixation coronary sinus lead. Eight months later, he complained of muscle contractions over device pocket. At fluoroscopy, coronary sinus lead was found near to pocket, outside of thoracic inlet. Atrial and ventricular leads were in normal position. After opening pocket, a short tract of coronary sinus lead appeared anteriorly dislocated to generator, while greater length of lead body twisted a reel behind. The distal part of lead was found outside venous entry at careful dissection. Atrial and ventricular leads were firmly anchored. Discussion : Our case is a selective 'Idiopathic' lead macrodislodgement, possibly due to a ratchet mechanism between the lead andAbstract: Background : 'Idiopathic' lead macrodislodgement may be due to Twiddler's syndrome depending on active twisting of pulse generator within subcutaneous pocket. All leads are involved, at any time from implantation, and frequently damaged. In the past few years, a reel syndrome was also observed: retraction of pacemaker leads into pocket without patient manipulation, owing to lead circling the generator. In other cases, a 'ratchet' mechanism has been postulated. Reel and ratchet mechanisms require loose anchoring, occur generally briefly after implantation, with non-damaged leads. We report the first case of an active-fixation coronary sinus lead selective macrodislodgement involving such ratchet mechanism. Case summary : A 65-year-old man underwent biventricular defibrillator device implantation, with active-fixation coronary sinus lead. Eight months later, he complained of muscle contractions over device pocket. At fluoroscopy, coronary sinus lead was found near to pocket, outside of thoracic inlet. Atrial and ventricular leads were in normal position. After opening pocket, a short tract of coronary sinus lead appeared anteriorly dislocated to generator, while greater length of lead body twisted a reel behind. The distal part of lead was found outside venous entry at careful dissection. Atrial and ventricular leads were firmly anchored. Discussion : Our case is a selective 'Idiopathic' lead macrodislodgement, possibly due to a ratchet mechanism between the lead and the suture sleeve, induced by normal arm motion; such mechanism incredibly, and for first time in literature involves a coronary sinus active-fixation lead. Conclusion : Careful attention should always be paid to secure anchoring even of active-fixation coronary sinus leads. … (more)
- Is Part Of:
- European heart journal. Volume 4:Issue 6(2020)
- Journal:
- European heart journal
- Issue:
- Volume 4:Issue 6(2020)
- Issue Display:
- Volume 4, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 4
- Issue:
- 6
- Issue Sort Value:
- 2020-0004-0006-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2020-12-28
- Subjects:
- Reel syndrome -- Twiddler's syndrome -- Ratchet mechanism -- Coronary sinus lead dislodgement -- Coronary sinus active-fixation lead -- Case report
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/ytaa466 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21693.xml