A case series of three patients with unilateral disconnected pulmonary artery supplied by an ipsilateral patent ductus arteriosus: neonatal ductal stenting as palliation to preserve pulmonary arterial patency. Issue 6 (18th November 2020)
- Record Type:
- Journal Article
- Title:
- A case series of three patients with unilateral disconnected pulmonary artery supplied by an ipsilateral patent ductus arteriosus: neonatal ductal stenting as palliation to preserve pulmonary arterial patency. Issue 6 (18th November 2020)
- Main Title:
- A case series of three patients with unilateral disconnected pulmonary artery supplied by an ipsilateral patent ductus arteriosus: neonatal ductal stenting as palliation to preserve pulmonary arterial patency
- Authors:
- Ho, Andrew B
Salmon, Tony P
Hribernik, Ines
Hayes, Nicholas
Thomson, John D
Bentham, James R - Editors:
- Sylvia, Krupickova
Christoph, Sinning
Filippo, Puricelli
Christian Fielder, Camm
Ross, Thomson - Abstract:
- Abstract: Background : Disconnected branch pulmonary arteries with a systemic arterial origin of the disconnected vessel is a rare, but well-described entity. Most will have ductal tissue connecting the pulmonary artery to the aorta. Case summary : We describe in this paper the haemodynamic result in three neonates presenting with ductal origin of a single branch pulmonary artery in the context of trans-catheter stenting procedures to maintain or re-recruit vessel patency. All were faced with potential or actual ductal closure and proceeded to trans-catheter stenting to re-cannalate the duct-dependent pulmonary artery. Two patients with otherwise normal anatomy struggled post-procedure with pulmonary hypertension and right ventricular dilatation. Both required surgical re-anastomosis of the disconnected pulmonary artery during the same admission—one 26 days post-stenting following failure to wean from high-flow respiratory support and the second 8 days post-stenting following failed extubation. In contrast, a patient with tetralogy of Fallot born at 2.5 kg underwent sequential stenting of the right ventricular outflow tract and then the left-sided ductus. He had a good post-procedural course and thrived for several months before complete repair. Discussion : We describe the clinical courses and discuss the resultant haemodynamics, highlighting the importance of flow to each lung, the resulting haemodynamic implications and the compounding effects of additional lesions.
- Is Part Of:
- European heart journal. Volume 4:Issue 6(2020)
- Journal:
- European heart journal
- Issue:
- Volume 4:Issue 6(2020)
- Issue Display:
- Volume 4, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 4
- Issue:
- 6
- Issue Sort Value:
- 2020-0004-0006-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2020-11-18
- Subjects:
- Patent arterial duct -- Pulmonary artery -- Stenting -- Case series
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/ytaa422 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21693.xml