MRI and CT Assessment of Abdominal Tissue Composition in Patients After High-Intensity Focused Electromagnetic Therapy Treatments: One-Year Follow-Up. (27th February 2020)
- Record Type:
- Journal Article
- Title:
- MRI and CT Assessment of Abdominal Tissue Composition in Patients After High-Intensity Focused Electromagnetic Therapy Treatments: One-Year Follow-Up. (27th February 2020)
- Main Title:
- MRI and CT Assessment of Abdominal Tissue Composition in Patients After High-Intensity Focused Electromagnetic Therapy Treatments: One-Year Follow-Up
- Authors:
- Kinney, Brian M
Kent, David E - Abstract:
- Abstract: Background: Several studies investigating high-intensity focused electromagnetic (HIFEM) treatments have recently been published. However, due to the novelty of the procedure, long-term data are still missing. Objectives: The aim of this study was to evaluate changes in abdominal tissues on average 1 year after a series of HIFEM treatments, to determine the long-term durability of patients' original body responses. Methods: Magnetic resonance imaging (MRI) or computed tomography (CT) scanning were performed on 21 patients a mean of 332.6 [88.5] days after their original HIFEM treatment series. The scans were evaluated by a blinded radiologist for abdominal muscle thickness, subcutaneous fat changes, and abdominal separation. The results were compared with the MRI/CT-assisted measurements taken at baseline and 6-week follow-up. Correlations between collected data sets were calculated and tested. The incidence of any adverse events related to earlier treatments was monitored. Results: When comparing the 1-year follow-up measurements with the baseline, the MRI/CT-assisted calculations revealed mean reductions of 14.63% (2.97 [2.11] mm) in fat, 19.05% (1.89 [0.88] mm) in muscle thickening, and 10.46% (1.96 [1.71] mm) in diastasis recti. All changes were significant ( P < 0.05) and not related to weight fluctuations ( P > 0.05). The baseline width of diastasis positively correlated with the degree of improvement at follow-up. No adverse events were reported.Abstract: Background: Several studies investigating high-intensity focused electromagnetic (HIFEM) treatments have recently been published. However, due to the novelty of the procedure, long-term data are still missing. Objectives: The aim of this study was to evaluate changes in abdominal tissues on average 1 year after a series of HIFEM treatments, to determine the long-term durability of patients' original body responses. Methods: Magnetic resonance imaging (MRI) or computed tomography (CT) scanning were performed on 21 patients a mean of 332.6 [88.5] days after their original HIFEM treatment series. The scans were evaluated by a blinded radiologist for abdominal muscle thickness, subcutaneous fat changes, and abdominal separation. The results were compared with the MRI/CT-assisted measurements taken at baseline and 6-week follow-up. Correlations between collected data sets were calculated and tested. The incidence of any adverse events related to earlier treatments was monitored. Results: When comparing the 1-year follow-up measurements with the baseline, the MRI/CT-assisted calculations revealed mean reductions of 14.63% (2.97 [2.11] mm) in fat, 19.05% (1.89 [0.88] mm) in muscle thickening, and 10.46% (1.96 [1.71] mm) in diastasis recti. All changes were significant ( P < 0.05) and not related to weight fluctuations ( P > 0.05). The baseline width of diastasis positively correlated with the degree of improvement at follow-up. No adverse events were reported. Conclusion: The HIFEM-induced muscle hypertrophy, fat reduction, and reduction in abdominal separation were maintained 1-year posttreatment. This suggests long-term durability of the original bodily response, which needs to be verified by continuing follow-up of this group and by further studies. Level of Evidence: 4: … (more)
- Is Part Of:
- Aesthetic surgery journal. Volume 40:Number 12(2020)
- Journal:
- Aesthetic surgery journal
- Issue:
- Volume 40:Number 12(2020)
- Issue Display:
- Volume 40, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 40
- Issue:
- 12
- Issue Sort Value:
- 2020-0040-0012-0000
- Page Start:
- NP686
- Page End:
- NP693
- Publication Date:
- 2020-02-27
- Subjects:
- Surgery, Plastic -- Periodicals
617.95 - Journal URLs:
- http://asj.oxfordjournals.org/content/ ↗
http://aes.sagepub.com/content/by/year ↗
http://www.mosby.com/aesthetic ↗
http://online.sagepub.com/ ↗
http://www.sciencedirect.com/science/journal/1090820X ↗ - DOI:
- 10.1093/asj/sjaa052 ↗
- Languages:
- English
- ISSNs:
- 1090-820X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0730.384000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21681.xml