Electromagnetic Navigation Bronchoscopy With Tomosynthesis-based Visualization and Positional Correction: Three-dimensional Accuracy as Confirmed by Cone-Beam Computed Tomography. Issue 1 (January 2021)
- Record Type:
- Journal Article
- Title:
- Electromagnetic Navigation Bronchoscopy With Tomosynthesis-based Visualization and Positional Correction: Three-dimensional Accuracy as Confirmed by Cone-Beam Computed Tomography. Issue 1 (January 2021)
- Main Title:
- Electromagnetic Navigation Bronchoscopy With Tomosynthesis-based Visualization and Positional Correction
- Authors:
- Pritchett, Michael A.
Bhadra, Krish
Mattingley, Jennifer S. - Abstract:
- Abstract : Background: Electromagnetic navigation bronchoscopy (ENB) aids in lung lesion biopsy. However, anatomic divergence between the preprocedural computed tomography (CT) and the actual bronchial anatomy during the procedure can limit localization accuracy. An advanced ENB system has been designed to mitigate CT-to-body divergence using a tomosynthesis-based software algorithm that enhances nodule visibility and allows for intraprocedural local registration. Materials and Methods: A prospective, 2-center study was conducted in subjects with single peripheral lung lesions ≥10 mm to assess localization accuracy of the superDimension navigation system with fluoroscopic navigation technology. Three-dimensional accuracy was confirmed by cone-beam computed tomography. Complications were assessed through 7 days. Results: Fifty subjects were enrolled (25 per site). Lesions were <20 mm in 61.2% (30/49). A bronchus sign was present in 53.1% (26/49). Local registration was completed in 95.9% (47/49). Three-dimensional target overlap (primary endpoint) was achieved in 59.6% (28/47) and 83.0% (39/47) before and after location correction, respectively. Excluding subjects with unevaluable video files, target overlap was achieved 68.3% (28/41) and 95.1% (39/41), respectively. Malignant results were obtained in 53.1% (26/49) by rapid on-site evaluation and 61.2% (30/49) by final pathology of the ENB-aided sample. Diagnostic yield was not evaluated. Procedure-related complications wereAbstract : Background: Electromagnetic navigation bronchoscopy (ENB) aids in lung lesion biopsy. However, anatomic divergence between the preprocedural computed tomography (CT) and the actual bronchial anatomy during the procedure can limit localization accuracy. An advanced ENB system has been designed to mitigate CT-to-body divergence using a tomosynthesis-based software algorithm that enhances nodule visibility and allows for intraprocedural local registration. Materials and Methods: A prospective, 2-center study was conducted in subjects with single peripheral lung lesions ≥10 mm to assess localization accuracy of the superDimension navigation system with fluoroscopic navigation technology. Three-dimensional accuracy was confirmed by cone-beam computed tomography. Complications were assessed through 7 days. Results: Fifty subjects were enrolled (25 per site). Lesions were <20 mm in 61.2% (30/49). A bronchus sign was present in 53.1% (26/49). Local registration was completed in 95.9% (47/49). Three-dimensional target overlap (primary endpoint) was achieved in 59.6% (28/47) and 83.0% (39/47) before and after location correction, respectively. Excluding subjects with unevaluable video files, target overlap was achieved 68.3% (28/41) and 95.1% (39/41), respectively. Malignant results were obtained in 53.1% (26/49) by rapid on-site evaluation and 61.2% (30/49) by final pathology of the ENB-aided sample. Diagnostic yield was not evaluated. Procedure-related complications were pneumothorax in 1 subject (no chest tube required) and scant hemoptysis in 3 subjects (no interventions required). Conclusion: ENB with tomosynthesis-based fluoroscopic navigation improved the 3-dimensional convergence between the virtual target and actual lung lesion as confirmed by cone-beam computed tomography. Future studies are necessary to understand the impact of this technology on diagnostic yield. … (more)
- Is Part Of:
- Journal of bronchology & interventional pulmonology. Volume 28:Issue 1(2021)
- Journal:
- Journal of bronchology & interventional pulmonology
- Issue:
- Volume 28:Issue 1(2021)
- Issue Display:
- Volume 28, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 28
- Issue:
- 1
- Issue Sort Value:
- 2021-0028-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- electromagnetic navigation bronchoscopy -- cone-beam computed tomography -- tomosynthesis -- fluoroscopic navigation -- lung cancer
Bronchoscopy -- Periodicals
Lungs -- Diseases -- Periodicals
Respiratory Tract Diseases -- Periodicals
Lung Diseases -- surgery -- Periodicals
Diagnostic Techniques, Respiratory System -- Periodicals
Bronchi
Bronchoscopy
Lungs -- Diseases
Periodicals
616.23 - Journal URLs:
- http://journals.lww.com/bronchology/pages/default.aspx ↗
http://www.bronchology.com ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=ovft&AN=01436970-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/LBR.0000000000000687 ↗
- Languages:
- English
- ISSNs:
- 1944-6586
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.553000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21712.xml