Comparison of single breath hyperpolarized 129Xe MRI with dynamic 19F MRI in cystic fibrosis lung disease. Issue 2 (8th August 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of single breath hyperpolarized 129Xe MRI with dynamic 19F MRI in cystic fibrosis lung disease. Issue 2 (8th August 2020)
- Main Title:
- Comparison of single breath hyperpolarized 129Xe MRI with dynamic 19F MRI in cystic fibrosis lung disease
- Authors:
- McCallister, Andrew
Chung, Sang Hun
Antonacci, Michael
Z. Powell, Margret
Ceppe, Agathe S.
Donaldson, Scott H.
Lee, Yueh Z.
Branca, Rosa Tamara
Goralski, Jennifer L. - Abstract:
- Abstract : Purpose: To quantitatively compare dynamic 19 F and single breath hyperpolarized 129 Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods: Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic 19 F and single breath 129 Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between 19 F early‐breath, 19 F maximum‐ventilation, 129 Xe low‐resolution, and 129 Xe high‐resolution images were compared. Dynamic 19 F images were used to determine gas wash‐in/out rates in regions of ventilation congruency and mismatch between 129 Xe and 19 F. Results: VDP values from high‐resolution 129 Xe images were greater than from low‐resolution images ( P = .001), although these values were significantly correlated (r = 0.68, P = .03). Early‐breath 19 F VDP and max‐vent 19 F VDP also showed significant correlation (r = 0.75, P = .012), with early‐breath 19 F VDP values being significantly greater ( P < .001). No correlation in VDP values were detected between either 19 F method or high‐res 129 Xe images. In addition, the location and volume of ventilation defects were often different when comparing 129 Xe and 19 F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash‐in and wash‐out. Conclusion:Abstract : Purpose: To quantitatively compare dynamic 19 F and single breath hyperpolarized 129 Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods: Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic 19 F and single breath 129 Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between 19 F early‐breath, 19 F maximum‐ventilation, 129 Xe low‐resolution, and 129 Xe high‐resolution images were compared. Dynamic 19 F images were used to determine gas wash‐in/out rates in regions of ventilation congruency and mismatch between 129 Xe and 19 F. Results: VDP values from high‐resolution 129 Xe images were greater than from low‐resolution images ( P = .001), although these values were significantly correlated (r = 0.68, P = .03). Early‐breath 19 F VDP and max‐vent 19 F VDP also showed significant correlation (r = 0.75, P = .012), with early‐breath 19 F VDP values being significantly greater ( P < .001). No correlation in VDP values were detected between either 19 F method or high‐res 129 Xe images. In addition, the location and volume of ventilation defects were often different when comparing 129 Xe and 19 F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash‐in and wash‐out. Conclusion: In CF subjects, ventilation abnormalities are identified by both 19 F and HP 129 Xe imaging. However, these ventilation abnormalities are not entirely congruent. 19 F and HP 129 Xe imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non‐ventilated regions in the lungs. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 2(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 2(2021)
- Issue Display:
- Volume 85, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 2
- Issue Sort Value:
- 2021-0085-0002-0000
- Page Start:
- 1028
- Page End:
- 1038
- Publication Date:
- 2020-08-08
- Subjects:
- cystic fibrosis -- hyperpolarized gas -- perflorinated gas imaging -- VDP -- ventilation defect
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28457 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21713.xml