Impact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement. Issue 2 (8th February 2016)
- Record Type:
- Journal Article
- Title:
- Impact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement. Issue 2 (8th February 2016)
- Main Title:
- Impact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
- Authors:
- Poulin, Frédéric
Yingchoncharoen, Teerapat
Wilson, William M.
Horlick, Eric M.
Généreux, Philippe
Tuzcu, E. Murat
Stewart, William
Osten, Mark D.
Woo, Anna
Thavendiranathan, Paaladinesh - Abstract:
- Abstract : Background: The aim of this study was to compare left ventricular (LV) remodeling using myocardial strain between patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) with and without prosthesis‐patient mismatch (PPM). Methods and Results: In a retrospective study, speckle‐tracking echocardiography was used to measure global longitudinal strain (GLS) and strain rate (GLSR), circumferential strain, and rotation before and at mid‐term follow‐up post‐TAVR. Moderate and severe PPM were defined as an effective orifice area ≤0.85 and <0.65 cm 2 /m 2, respectively. A total of 102 patients (median age, 83 years [77–88]) with severe AS were included. At 6±3 months post‐TAVR, moderate and severe PPM were found in 32 (31%) and 9 (9%) patients. Patients without PPM had a significant regression in LV mass (from 134±41 to 119±38 g/m 2 ; P =0.001) at follow‐up whereas those with PPM did not. There was a significant improvement in LV GLS (−12.8±4.0 to −14.3±4.3%; P =0.01), GLSR (−0.61±0.20 to −0.73±0.25 second −1 ; P <0.001), and early diastolic strain rate (0.52±0.20 to 0.64±0.20 second −1 ; P <0.001) in patients without PPM, but not in those with PPM. After adjustment for pre‐TAVR ejection fraction and post‐TAVR aortic regurgitation, patients without PPM had greater improvement in LV longitudinal strain parameters compared to those with PPM. After a median follow‐up of 46.1 months (interquartile range, 35.4–60.8), there was noAbstract : Background: The aim of this study was to compare left ventricular (LV) remodeling using myocardial strain between patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) with and without prosthesis‐patient mismatch (PPM). Methods and Results: In a retrospective study, speckle‐tracking echocardiography was used to measure global longitudinal strain (GLS) and strain rate (GLSR), circumferential strain, and rotation before and at mid‐term follow‐up post‐TAVR. Moderate and severe PPM were defined as an effective orifice area ≤0.85 and <0.65 cm 2 /m 2, respectively. A total of 102 patients (median age, 83 years [77–88]) with severe AS were included. At 6±3 months post‐TAVR, moderate and severe PPM were found in 32 (31%) and 9 (9%) patients. Patients without PPM had a significant regression in LV mass (from 134±41 to 119±38 g/m 2 ; P =0.001) at follow‐up whereas those with PPM did not. There was a significant improvement in LV GLS (−12.8±4.0 to −14.3±4.3%; P =0.01), GLSR (−0.61±0.20 to −0.73±0.25 second −1 ; P <0.001), and early diastolic strain rate (0.52±0.20 to 0.64±0.20 second −1 ; P <0.001) in patients without PPM, but not in those with PPM. After adjustment for pre‐TAVR ejection fraction and post‐TAVR aortic regurgitation, patients without PPM had greater improvement in LV longitudinal strain parameters compared to those with PPM. After a median follow‐up of 46.1 months (interquartile range, 35.4–60.8), there was no difference in survival between patients with and without PPM. Conclusions: TAVR was associated with an incidence of PPM of 40%. Greater reverse LV remodeling using myocardial strain was evident in patients without PPM compared to PPM. Presence of PPM was not associated with mortality. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 5:Issue 2(2016)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 5:Issue 2(2016)
- Issue Display:
- Volume 5, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 5
- Issue:
- 2
- Issue Sort Value:
- 2016-0005-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-02-08
- Subjects:
- aortic stenosis -- effective orifice area -- prosthesis‐patient mismatch -- speckle‐tracking echocardiography -- strain -- transcatheter aortic valve replacement
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.115.002866 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21681.xml