Analysis of a coupled fluid‐structure interaction model of the left atrium and mitral valve. (23rd December 2019)
- Record Type:
- Journal Article
- Title:
- Analysis of a coupled fluid‐structure interaction model of the left atrium and mitral valve. (23rd December 2019)
- Main Title:
- Analysis of a coupled fluid‐structure interaction model of the left atrium and mitral valve
- Authors:
- Feng, Liuyang
Gao, Hao
Griffith, Boyce
Niederer, Steven
Luo, Xiaoyu - Abstract:
- Abstract: We present a coupled left atrium‐mitral valve model based on computed tomography scans with fibre‐reinforced hyperelastic materials. Fluid‐structure interaction is realised by using an immersed boundary‐finite element framework. Effects of pathological conditions, eg, mitral valve regurgitation and atrial fibrillation, and geometric and structural variations, namely, uniform vs non‐uniform atrial wall thickness and rule‐based vs atlas‐based fibre architectures, on the system are investigated. We show that in the case of atrial fibrillation, pulmonary venous flow reversal at late diastole disappears, and the filling waves at the left atrial appendage orifice during systole have reduced magnitude. In the case of mitral regurgitation, a higher atrial pressure and disturbed flows are seen, especially during systole, when a large regurgitant jet can be found with the suppressed pulmonary venous flow. We also show that both the rule‐based and atlas‐based fibre defining methods lead to similar flow fields and atrial wall deformations. However, the changes in wall thickness from non‐uniform to uniform tend to underestimate the atrial deformation. Using a uniform but thickened wall also lowers the overall strain level. The flow velocity within the left atrial appendage, which is important in terms of appendage thrombosis, increases with the thickness of the left atrial wall. Energy analysis shows that the kinetic and dissipation energies of the flow within the left atriumAbstract: We present a coupled left atrium‐mitral valve model based on computed tomography scans with fibre‐reinforced hyperelastic materials. Fluid‐structure interaction is realised by using an immersed boundary‐finite element framework. Effects of pathological conditions, eg, mitral valve regurgitation and atrial fibrillation, and geometric and structural variations, namely, uniform vs non‐uniform atrial wall thickness and rule‐based vs atlas‐based fibre architectures, on the system are investigated. We show that in the case of atrial fibrillation, pulmonary venous flow reversal at late diastole disappears, and the filling waves at the left atrial appendage orifice during systole have reduced magnitude. In the case of mitral regurgitation, a higher atrial pressure and disturbed flows are seen, especially during systole, when a large regurgitant jet can be found with the suppressed pulmonary venous flow. We also show that both the rule‐based and atlas‐based fibre defining methods lead to similar flow fields and atrial wall deformations. However, the changes in wall thickness from non‐uniform to uniform tend to underestimate the atrial deformation. Using a uniform but thickened wall also lowers the overall strain level. The flow velocity within the left atrial appendage, which is important in terms of appendage thrombosis, increases with the thickness of the left atrial wall. Energy analysis shows that the kinetic and dissipation energies of the flow within the left atrium are altered differently by atrial fibrillation and mitral valve regurgitation, providing a useful indication of the atrial performance in pathological situations. Abstract : We present a coupled left atrium‐mitral valve model based on computed tomography scans with fibre‐reinforced hyperelastic materials. Fluid‐structure interaction is realised by using an immersed boundary‐finite element framework. Effects of pathological conditions, eg, mitral valve regurgitation and atrial fibrillation, and geometric and structural variations, namely, uniform vs non‐uniform atrial wall thickness and rule‐based vs atlas‐based fibre architectures, on the system are investigated. … (more)
- Is Part Of:
- International journal for numerical methods in biomedical engineering. Volume 35:Number 11(2019)
- Journal:
- International journal for numerical methods in biomedical engineering
- Issue:
- Volume 35:Number 11(2019)
- Issue Display:
- Volume 35, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 35
- Issue:
- 11
- Issue Sort Value:
- 2019-0035-0011-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-12-23
- Subjects:
- atrial fibrillation -- fibre‐reinforced hyperelastic material -- fibre structure -- fluid‐structure interaction -- left atrial appendage -- left atrium -- mitral regurgitation -- mitral valve
Biomedical engineering -- Periodicals
Imaging systems in medicine -- Periodicals
Numerical analysis -- Periodicals
Engineering mathematics -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2040-7947 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cnm.3254 ↗
- Languages:
- English
- ISSNs:
- 2040-7939
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.403550
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: