Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study. (August 2022)
- Record Type:
- Journal Article
- Title:
- Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study. (August 2022)
- Main Title:
- Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study
- Authors:
- Gauci, Marc-Olivier
Chaoui, Jean
Berhouet, Julien
Jacquot, Adrien
Walch, Gilles
Boileau, Pascal - Abstract:
- Background: Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. Patients and Methods: Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 76 ± 6 yo) and impingements were analyzed. Inlay (155°-inclined) and Onlay (145°-inclined) humeral designs were tested. Four configurations were tested for each shoulder: "INLAY": non-lateralized glenoid-inlay humerus, "BIO-INLAY": lateralized glenoid (BIO-RSA)-inlay humerus, "ONLAY": non-lateralized glenoid-onlay humerus, and "BIO-ONLAY": lateralized (BIO-RSA) glenoid-onlay humerus. Results: BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion ( p < 0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion ( p < 0.0001) and did not depend on the lateralization. Conclusion: Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145° inclination. GreaterBackground: Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. Patients and Methods: Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 76 ± 6 yo) and impingements were analyzed. Inlay (155°-inclined) and Onlay (145°-inclined) humeral designs were tested. Four configurations were tested for each shoulder: "INLAY": non-lateralized glenoid-inlay humerus, "BIO-INLAY": lateralized glenoid (BIO-RSA)-inlay humerus, "ONLAY": non-lateralized glenoid-onlay humerus, and "BIO-ONLAY": lateralized (BIO-RSA) glenoid-onlay humerus. Results: BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion ( p < 0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion ( p < 0.0001) and did not depend on the lateralization. Conclusion: Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145° inclination. Greater tuberosity abutment has to be avoided in abduction and the Inlay design provides the best abduction. … (more)
- Is Part Of:
- Shoulder & elbow. Volume 14:Number 4(2022)
- Journal:
- Shoulder & elbow
- Issue:
- Volume 14:Number 4(2022)
- Issue Display:
- Volume 14, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 4
- Issue Sort Value:
- 2022-0014-0004-0000
- Page Start:
- 385
- Page End:
- 394
- Publication Date:
- 2022-08
- Subjects:
- Range of motion -- 3D planning -- reverse shoulder arthroplasty -- notching -- glenoid lateralization
Elbow -- Diseases -- Periodicals
Elbow -- Surgery -- Periodicals
Shoulder -- Diseases -- Periodicals
Shoulder -- Surgery -- Periodicals
Shoulder -- Periodicals
Elbow -- Periodicals
Shoulder Joint -- Periodicals
Elbow Joint -- Periodicals
617.572005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=718387 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1758-5740 ↗
http://journals.sagepub.com/home/sel ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1758573221994141 ↗
- Languages:
- English
- ISSNs:
- 1758-5732
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21654.xml