Anodization of medical grade stainless steel for improved corrosion resistance and nanostructure formation targeting biomedical applications. (1st June 2022)
- Record Type:
- Journal Article
- Title:
- Anodization of medical grade stainless steel for improved corrosion resistance and nanostructure formation targeting biomedical applications. (1st June 2022)
- Main Title:
- Anodization of medical grade stainless steel for improved corrosion resistance and nanostructure formation targeting biomedical applications
- Authors:
- Herath, Indika
Davies, Joseph
Will, Geoffrey
Tran, Phong A.
Velic, Amar
Sarvghad, Madjid
Islam, Majedul
Paritala, Phani Kumari
Jaggessar, Alka
Schuetz, Michael
Chatterjee, Kaushik
Yarlagadda, Prasad K.D.V. - Abstract:
- Abstract: Stainless steel is extensively used in various biomedical engineering and hospital applications, including surgical equipment and furniture. Strong adhesion of bacteria and viruses on metal surfaces can restrict long-term utilization for biomedical applications. This study aims to develop an improved electrochemical etching protocol for the anodization of 316 L grade stainless steel (10 × 15 mm) to fabricate nanostructures for biomedical and hospital applications. Anodizing conditions were optimized using two different electrolyte solutions; HNO3 : H2 SO4 (1:1) and HNO3, by varying applied potential, electrolyte concentration and anodizing time. Morphology and topography of the anodized surfaces were characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM) and scanning Kelvin probe force microscopy (SKPFM). AC and DC electrochemical techniques were used to further characterize the corrosion behaviour of the nanostructured surfaces. Electrochemical optimization produced two different nanostructured surfaces with the anodizing conditions of (1) 50% HNO3 at 0.465 A/cm 2 for 1 min (surface 1), and (2) 0.5 M HNO3 + H2 SO4 (1:1) at 0.366 A/cm 2 for 5 min (surface 2). Both processes produced nanoscale surface roughness with varying corrosion susceptibility. Surfaces anodized using 50% HNO3 comprised of 'hierarchical roughness' with dense spikes (10 – 20 nm in diameter), covering rock candy-like protrusion (10 - 15 µm diameter). Whereas theAbstract: Stainless steel is extensively used in various biomedical engineering and hospital applications, including surgical equipment and furniture. Strong adhesion of bacteria and viruses on metal surfaces can restrict long-term utilization for biomedical applications. This study aims to develop an improved electrochemical etching protocol for the anodization of 316 L grade stainless steel (10 × 15 mm) to fabricate nanostructures for biomedical and hospital applications. Anodizing conditions were optimized using two different electrolyte solutions; HNO3 : H2 SO4 (1:1) and HNO3, by varying applied potential, electrolyte concentration and anodizing time. Morphology and topography of the anodized surfaces were characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM) and scanning Kelvin probe force microscopy (SKPFM). AC and DC electrochemical techniques were used to further characterize the corrosion behaviour of the nanostructured surfaces. Electrochemical optimization produced two different nanostructured surfaces with the anodizing conditions of (1) 50% HNO3 at 0.465 A/cm 2 for 1 min (surface 1), and (2) 0.5 M HNO3 + H2 SO4 (1:1) at 0.366 A/cm 2 for 5 min (surface 2). Both processes produced nanoscale surface roughness with varying corrosion susceptibility. Surfaces anodized using 50% HNO3 comprised of 'hierarchical roughness' with dense spikes (10 – 20 nm in diameter), covering rock candy-like protrusion (10 - 15 µm diameter). Whereas the second set of conditions produced single scale roughness with a terrace-like topography with nanoscale ridges of 34.8 ± 1.2 nm in width atop microscale hills. Surface 2 possessed improved corrosion resistance through the formation an oxide film, while the surface 1 was more susceptible to corrosion. Overall, this study demonstrates the importance of the careful optimization of electrochemical surface treatment for medical grade stainless steel in terms of roughness of nanostructures and corrosion susceptibility. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- Electrochimica acta. Volume 416(2022)
- Journal:
- Electrochimica acta
- Issue:
- Volume 416(2022)
- Issue Display:
- Volume 416, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 416
- Issue:
- 2022
- Issue Sort Value:
- 2022-0416-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-01
- Subjects:
- Biomedical -- Corrosion -- Electrochemical etching -- Nanostructures -- Stainless steel
Electrochemistry -- Periodicals
Electrochemistry, Industrial -- Periodicals
541.37 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00134686 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.electacta.2022.140274 ↗
- Languages:
- English
- ISSNs:
- 0013-4686
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.950000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21649.xml