Fiberoptic-guided nerve integrity monitoring tube intubation assisted by video-laryngoscope with external laryngeal manipulation in a patient with anteriorly displaced larynx due to huge goiter with retropharyngeal involvement: A case report. Issue 10 (11th March 2022)
- Record Type:
- Journal Article
- Title:
- Fiberoptic-guided nerve integrity monitoring tube intubation assisted by video-laryngoscope with external laryngeal manipulation in a patient with anteriorly displaced larynx due to huge goiter with retropharyngeal involvement: A case report. Issue 10 (11th March 2022)
- Main Title:
- Fiberoptic-guided nerve integrity monitoring tube intubation assisted by video-laryngoscope with external laryngeal manipulation in a patient with anteriorly displaced larynx due to huge goiter with retropharyngeal involvement
- Authors:
- Kim, Ji-Yoon
Yeom, Ji-Yong
Youn, Si-Jeong
Lee, Jeong-Eun
Oh, Jin-Young
Byun, Sung-Hye - Other Names:
- Saranathan. Maya section editor.
- Abstract:
- Abstract: Rationale: Goiter, an abnormal enlargement of the thyroid gland, can induce airway distortion or tracheal compression. Airway management can be challenging for anesthesiologists, depending on the location and size of the mass as well as the patient's airway conditions, although it is reported that most cases can easily be managed by oral intubation. Patient concerns: A 61-year-old female patient who had planned for a total thyroidectomy due to a huge goiter was intubated with nerve integrity monitoring (NIM) tubes, using video laryngoscopy (VL) and oral fiberoptic bronchoscopy (FOB) alone. The respective attempts initially failed. Diagnosis: The patient's thyroid mass extended from the C3 cervical spine level to the T1 thoracic spine level with retropharyngeal involvement, causing an upper airway anatomical alteration that made intubation difficult. FOB manipulation was challenging due to the acute angulation of the laryngeal inlet and the tongue and the consequent interruption by the epiglottis. There was resistance to tube introduction, despite counterclockwise rotation of the NIM tube, due to acute angulation of the larynx and circumferential narrowing of the oropharyngeal and supraglottic space. Interventions: In the first step of FOB-guided intubation, external laryngeal manipulation (ELM) was performed to improve the angle of the glottic opening and to elevate epiglottis tip. This allowed for FOB introduction into the trachea. VL was then performedAbstract: Rationale: Goiter, an abnormal enlargement of the thyroid gland, can induce airway distortion or tracheal compression. Airway management can be challenging for anesthesiologists, depending on the location and size of the mass as well as the patient's airway conditions, although it is reported that most cases can easily be managed by oral intubation. Patient concerns: A 61-year-old female patient who had planned for a total thyroidectomy due to a huge goiter was intubated with nerve integrity monitoring (NIM) tubes, using video laryngoscopy (VL) and oral fiberoptic bronchoscopy (FOB) alone. The respective attempts initially failed. Diagnosis: The patient's thyroid mass extended from the C3 cervical spine level to the T1 thoracic spine level with retropharyngeal involvement, causing an upper airway anatomical alteration that made intubation difficult. FOB manipulation was challenging due to the acute angulation of the laryngeal inlet and the tongue and the consequent interruption by the epiglottis. There was resistance to tube introduction, despite counterclockwise rotation of the NIM tube, due to acute angulation of the larynx and circumferential narrowing of the oropharyngeal and supraglottic space. Interventions: In the first step of FOB-guided intubation, external laryngeal manipulation (ELM) was performed to improve the angle of the glottic opening and to elevate epiglottis tip. This allowed for FOB introduction into the trachea. VL was then performed transorally to elevate the tongue base and increase space, using the blade. ELM was applied simultaneously to move the glottis lower, thereby reducing the angle of the tube passage. Outcomes: The NIM tube was successfully introduced into the trachea with counterclockwise rotation in FOB-guided intubation. Lessons: The combination of techniques using basic and popular devices and maneuvers, such as ELM and VL, may be useful for the successful management of difficult airways related to retropharyngeal goiter, without the need for surgical airway. … (more)
- Is Part Of:
- Medicine. Volume 101:Issue 10(2022)
- Journal:
- Medicine
- Issue:
- Volume 101:Issue 10(2022)
- Issue Display:
- Volume 101, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 101
- Issue:
- 10
- Issue Sort Value:
- 2022-0101-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03-11
- Subjects:
- difficult airway -- external laryngeal manipulation -- fiberoptic bronchoscopy -- goiter -- videolaryngoscopy
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000029041 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21645.xml