Transformation of Physical DVHs to Radiobiologically Equivalent Ones in Hypofractionated Radiotherapy Analyzing Dosimetric and Clinical Parameters: A Practical Approach for Routine Clinical Practice in Radiation Oncology. (19th November 2013)
- Record Type:
- Journal Article
- Title:
- Transformation of Physical DVHs to Radiobiologically Equivalent Ones in Hypofractionated Radiotherapy Analyzing Dosimetric and Clinical Parameters: A Practical Approach for Routine Clinical Practice in Radiation Oncology. (19th November 2013)
- Main Title:
- Transformation of Physical DVHs to Radiobiologically Equivalent Ones in Hypofractionated Radiotherapy Analyzing Dosimetric and Clinical Parameters: A Practical Approach for Routine Clinical Practice in Radiation Oncology
- Authors:
- Thrapsanioti, Zoi
Karanasiou, Irene
Platoni, Kalliopi
Efstathopoulos, Efstathios P.
Matsopoulos, George
Dilvoi, Maria
Patatoukas, George
Chaldeopoulos, Demetrios
Kelekis, Nikolaos
Kouloulias, Vassilis - Other Names:
- Palmans Hugo Academic Editor.
- Abstract:
- Abstract : Purpose . The purpose of this study was to transform DVHs from physical to radiobiological ones as well as to evaluate their reliability by correlations of dosimetric and clinical parameters for 50 patients with prostate cancer and 50 patients with breast cancer, who were submitted to Hypofractionated Radiotherapy. Methods and Materials . To achieve this transformation, we used both the linear-quadratic model (LQ model) and the Niemierko model. The outcome of radiobiological DVHs was correlated with acute toxicity score according to EORTC/RTOG criteria. Results . Concerning the prostate radiotherapy, there was a significant correlation between RTOG acute rectal toxicity and D 50 (P < 0.001 ) and V 60 (P = 0.001 ) dosimetric parameters, calculated for α / β = 10 Gy. Moreover, concerning the breast radiotherapy there was a significant correlation between RTOG skin toxicity and V ≥ 60 dosimetric parameter, calculated for both α / β = 2.3 Gy (P < 0.001 ) and α / β = 10 Gy (P < 0.001 ). The new tool seems reliable and user-friendly. Conclusions . Our proposed model seems user-friendly. Its reliability in terms of agreement with the presented acute radiation induced toxicity was satisfactory. However, more patients are needed to extract safe conclusions.
- Is Part Of:
- Computational and mathematical methods in medicine. Volume 2013(2013)
- Journal:
- Computational and mathematical methods in medicine
- Issue:
- Volume 2013(2013)
- Issue Display:
- Volume 2013, Issue 2013 (2013)
- Year:
- 2013
- Volume:
- 2013
- Issue:
- 2013
- Issue Sort Value:
- 2013-2013-2013-0000
- Page Start:
- Page End:
- Publication Date:
- 2013-11-19
- Subjects:
- Medicine -- Computer simulation -- Periodicals
Medicine -- Mathematical models -- Periodicals
610.11 - Journal URLs:
- https://www.hindawi.com/journals/cmmm/ ↗
- DOI:
- 10.1155/2013/713420 ↗
- Languages:
- English
- ISSNs:
- 1748-670X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3390.573000
British Library HMNTS - ELD Digital store - Ingest File:
- 21637.xml