Moshirfar, Majid - Abstract:
- ABSTRACT: Purpose: To compare the inter-device agreement of anterior chamber depth (ACD), central corneal thickness (CCT), flat keratometry (K1), steep keratometry (K2), corneal astigmatism (ΔK), and white-to-white (WTW) measurements. Methods: This is a retrospective study with 73 myopic patients (142 eyes). We extracted and compared anterior segment measurements (ACD, CCT, K1, K2, ΔK, and WTW) of four devices (OPD-Scan III, Pentacam HR, Lenstar LS 900, and Galilei G4), and performed pairwise agreement comparisons between them. Results: Agreement analyses revealed that the most agreement occurred: in Pentacam HR and Galilei G4 for ACD measurements, in Pentacam HR and Lenstar LS 900 for CCT measurements, in OPD-Scan III and Galilei G4 for WTW measurements, in OPD-Scan III and Pentacam HR for K1 and K2 measurements, and OPD-Scan III and Galilei G4 for ΔK measurements. Conclusion: OPD-Scan III is interchangeable with both Galilei G4 and Lenstar LS 900 for WTW measurements. OPD-Scan III and the Pentacam-HR are interchangeable in K1, K2, and ΔK measurements. OPD-Scan III and Lenstar LS 900, and OPD-Scan III and Galilei G4 are interchangeable in K1 and ΔK measurements, respectively.
- Is Part Of:
- Expert review of medical devices. Volume 18:Number 12(2021)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 18:Number 12(2021)
- Issue Display:
- Volume 18, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 18
- Issue:
- 12
- Issue Sort Value:
- 2021-0018-0012-0000
- Page Start:
- 1235
- Page End:
- 1243
- Publication Date:
- 2021-12-02
- Subjects:
- Agreement -- anterior chamber depth -- anterior segment measurements -- central corneal thickness -- comparison -- device interchangeability -- keratometry -- white-to-white
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2021.2012153 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 21633.xml