Evaluation of a contactless neonatal physiological monitor in Nairobi, Kenya. Issue 6 (5th November 2021)
- Record Type:
- Journal Article
- Title:
- Evaluation of a contactless neonatal physiological monitor in Nairobi, Kenya. Issue 6 (5th November 2021)
- Main Title:
- Evaluation of a contactless neonatal physiological monitor in Nairobi, Kenya
- Authors:
- Wang, Dee
Macharia, William M
Ochieng, Roseline
Chomba, Dorothy
Hadida, Yifat S
Karasik, Roman
Dunsmuir, Dustin
Coleman, Jesse
Zhou, Guohai
Ginsburg, Amy Sarah
Ansermino, J Mark - Abstract:
- Abstract : Background: Globally, 2.5 million neonates died in 2018, accounting for 46% of under-5 deaths. Multiparameter continuous physiological monitoring (MCPM) of neonates allows for early detection and treatment of life-threatening health problems. However, neonatal monitoring technology is largely unavailable in low-resource settings. Methods: In four evaluation rounds, we prospectively compared the accuracy of the EarlySense under-mattress device to the Masimo Rad-97 pulse CO-oximeter with capnography reference device for heart rate (HR) and respiratory rate (RR) measurements in neonates in Kenya. EarlySense algorithm optimisations were made between evaluation rounds. In each evaluation round, we compared 200 randomly selected epochs of data using Bland-Altman plots and generated Clarke error grids with zones of 20% to aid in clinical interpretation. Results: Between 9 July 2019 and 8 January 2020, we collected 280 hours of MCPM data from 76 enrolled neonates. At the final evaluation round, the EarlySense MCPM device demonstrated a bias of −0.8 beats/minute for HR and 1.6 breaths/minute for RR, and normalised spread between the 95% upper and lower limits of agreement of 6.2% for HR and 27.3% for RR. Agreement between the two MCPM devices met the a priori–defined threshold of 30%. The Clarke error grids showed that all observations for HR and 197/200 for RR were within a 20% difference. Conclusion: Our research indicates that there is acceptable agreement between theAbstract : Background: Globally, 2.5 million neonates died in 2018, accounting for 46% of under-5 deaths. Multiparameter continuous physiological monitoring (MCPM) of neonates allows for early detection and treatment of life-threatening health problems. However, neonatal monitoring technology is largely unavailable in low-resource settings. Methods: In four evaluation rounds, we prospectively compared the accuracy of the EarlySense under-mattress device to the Masimo Rad-97 pulse CO-oximeter with capnography reference device for heart rate (HR) and respiratory rate (RR) measurements in neonates in Kenya. EarlySense algorithm optimisations were made between evaluation rounds. In each evaluation round, we compared 200 randomly selected epochs of data using Bland-Altman plots and generated Clarke error grids with zones of 20% to aid in clinical interpretation. Results: Between 9 July 2019 and 8 January 2020, we collected 280 hours of MCPM data from 76 enrolled neonates. At the final evaluation round, the EarlySense MCPM device demonstrated a bias of −0.8 beats/minute for HR and 1.6 breaths/minute for RR, and normalised spread between the 95% upper and lower limits of agreement of 6.2% for HR and 27.3% for RR. Agreement between the two MCPM devices met the a priori–defined threshold of 30%. The Clarke error grids showed that all observations for HR and 197/200 for RR were within a 20% difference. Conclusion: Our research indicates that there is acceptable agreement between the EarlySense and Masimo MCPM devices in the context of large within-subject variability; however, further studies establishing cost-effectiveness and clinical effectiveness are needed before large-scale implementation of the EarlySense MCPM device in neonates. Trial registration number: NCT03920761 . … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 107:Issue 6(2022)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 107:Issue 6(2022)
- Issue Display:
- Volume 107, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 107
- Issue:
- 6
- Issue Sort Value:
- 2022-0107-0006-0000
- Page Start:
- 558
- Page End:
- 564
- Publication Date:
- 2021-11-05
- Subjects:
- technology -- intensive care units -- neonatal -- neonatology
Children -- Diseases -- Periodicals
Infants -- Diseases -- Periodicals
618.920005 - Journal URLs:
- http://adc.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2021-322344 ↗
- Languages:
- English
- ISSNs:
- 0003-9888
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21615.xml