Investigating the accuracy and precision of TE‐dependent versus multi‐echo QSM using Laplacian‐based methods at 3 T. Issue 6 (3rd June 2020)
- Record Type:
- Journal Article
- Title:
- Investigating the accuracy and precision of TE‐dependent versus multi‐echo QSM using Laplacian‐based methods at 3 T. Issue 6 (3rd June 2020)
- Main Title:
- Investigating the accuracy and precision of TE‐dependent versus multi‐echo QSM using Laplacian‐based methods at 3 T
- Authors:
- Biondetti, Emma
Karsa, Anita
Thomas, David L.
Shmueli, Karin - Abstract:
- Abstract : Purpose: Multi‐echo gradient‐recalled echo acquisitions for QSM enable optimizing the SNR for several tissue types through multi‐echo (TE) combination or investigating temporal variations in the susceptibility (potentially reflecting tissue microstructure) by calculating one QSM image at each TE (TE‐dependent QSM). In contrast with multi‐echo QSM, applying Laplacian‐based methods (LBMs) for phase unwrapping and background field removal to single TEs could introduce nonlinear temporal variations (independent of tissue microstructure) into the measured susceptibility. Here, we aimed to compare the effect of LBMs on the QSM susceptibilities in TE‐dependent versus multi‐echo QSM. Methods: TE–dependent recalled echo data simulated in a numerical head phantom and gradient‐recalled echo images acquired at 3 T in 10 healthy volunteers. Several QSM pipelines were tested, including four distinct LBMs: sophisticated harmonic artifact reduction for phase data (SHARP), variable‐radius sophisticated harmonic artifact reduction for phase data (V‐SHARP), Laplacian boundary value background field removal (LBV), and one‐step total generalized variation (TGV). Results from distinct pipelines were compared using visual inspection, summary statistics of susceptibility in deep gray matter/white matter/venous regions of interest, and, in the healthy volunteers, regional susceptibility bias analysis and nonparametric tests. Results: Multi‐echo versus TE‐dependent QSM had higher regionalAbstract : Purpose: Multi‐echo gradient‐recalled echo acquisitions for QSM enable optimizing the SNR for several tissue types through multi‐echo (TE) combination or investigating temporal variations in the susceptibility (potentially reflecting tissue microstructure) by calculating one QSM image at each TE (TE‐dependent QSM). In contrast with multi‐echo QSM, applying Laplacian‐based methods (LBMs) for phase unwrapping and background field removal to single TEs could introduce nonlinear temporal variations (independent of tissue microstructure) into the measured susceptibility. Here, we aimed to compare the effect of LBMs on the QSM susceptibilities in TE‐dependent versus multi‐echo QSM. Methods: TE–dependent recalled echo data simulated in a numerical head phantom and gradient‐recalled echo images acquired at 3 T in 10 healthy volunteers. Several QSM pipelines were tested, including four distinct LBMs: sophisticated harmonic artifact reduction for phase data (SHARP), variable‐radius sophisticated harmonic artifact reduction for phase data (V‐SHARP), Laplacian boundary value background field removal (LBV), and one‐step total generalized variation (TGV). Results from distinct pipelines were compared using visual inspection, summary statistics of susceptibility in deep gray matter/white matter/venous regions of interest, and, in the healthy volunteers, regional susceptibility bias analysis and nonparametric tests. Results: Multi‐echo versus TE‐dependent QSM had higher regional accuracy, especially in high‐susceptibility regions and at shorter TEs. Everywhere except in the veins, a processing pipeline incorporating TGV provided the most temporally stable TE‐dependent QSM results with an accuracy similar to multi‐echo QSM. Conclusions: For TE‐dependent QSM, carefully choosing LBMs can minimize the introduction of LBM‐related nonlinear temporal susceptibility variations. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 6(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 6(2020)
- Issue Display:
- Volume 84, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 6
- Issue Sort Value:
- 2020-0084-0006-0000
- Page Start:
- 3040
- Page End:
- 3053
- Publication Date:
- 2020-06-03
- Subjects:
- magnetic resonance imaging -- multi‐echo QSM -- quantitative susceptibility mapping -- single‐echo QSM -- TE‐dependent QSM
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28331 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21621.xml