Energy performance and the discrepancy of multiple NetZero Energy Homes (NZEHs) in cold regions. (20th January 2018)
- Record Type:
- Journal Article
- Title:
- Energy performance and the discrepancy of multiple NetZero Energy Homes (NZEHs) in cold regions. (20th January 2018)
- Main Title:
- Energy performance and the discrepancy of multiple NetZero Energy Homes (NZEHs) in cold regions
- Authors:
- Li, Hong Xian
Chen, Yuan
Gül, Mustafa
Yu, Haitao
Al-Hussein, Mohamed - Abstract:
- Abstract: A NetZero Energy Home (NZEH) is designed, modelled, and constructed to produce as much energy as it consumes on an annual basis, with the required energy generated from renewable resources. However, the actual performance of an NZEH may vary from the design objective, and the performance of a given NZEH may differ from other NZEHs. In order to examine the actual energy performance and identify discrepancies among multiple NZEHs, a research project has been initiated in which six NZEHs in Edmonton and Calgary, Canada, built by Landmark Group of Companies, are monitored, assessed, and compared in this research. Complete annual data has been collected for four of the NZEHs to date, and the results show the average energy balance, excluding the NZEH with a period of non-occupancy (listed for sale), reaches −1.4%, which is very near the targeted balance. The actual energy performance is analyzed and compared for the monitored NZEHs by category, including space heating, domestic hot water (DHW) heating, ventilator, and base loads (including major appliances). Overall, space heating and cooling are found to account for more than 50% of the total energy usage of the NZEHs, except for one listed for sale; all the base loads of the analyzed NZEHs are lower than the base load predicted in HOT2000 (19.5 kWh/day). The factors contributing to energy performance variations are also analyzed by category in this paper. This research thus addresses the actual energy performance andAbstract: A NetZero Energy Home (NZEH) is designed, modelled, and constructed to produce as much energy as it consumes on an annual basis, with the required energy generated from renewable resources. However, the actual performance of an NZEH may vary from the design objective, and the performance of a given NZEH may differ from other NZEHs. In order to examine the actual energy performance and identify discrepancies among multiple NZEHs, a research project has been initiated in which six NZEHs in Edmonton and Calgary, Canada, built by Landmark Group of Companies, are monitored, assessed, and compared in this research. Complete annual data has been collected for four of the NZEHs to date, and the results show the average energy balance, excluding the NZEH with a period of non-occupancy (listed for sale), reaches −1.4%, which is very near the targeted balance. The actual energy performance is analyzed and compared for the monitored NZEHs by category, including space heating, domestic hot water (DHW) heating, ventilator, and base loads (including major appliances). Overall, space heating and cooling are found to account for more than 50% of the total energy usage of the NZEHs, except for one listed for sale; all the base loads of the analyzed NZEHs are lower than the base load predicted in HOT2000 (19.5 kWh/day). The factors contributing to energy performance variations are also analyzed by category in this paper. This research thus addresses the actual energy performance and discrepancies among multiple NZEHs in cold regions; the research results can be referenced to improve building operation and future design of NZEHs. Highlights: Monitoring of the energy performance of multiple NZEHs is presented. The average energy balance was −1.4%, close to the zero energy balance target. The energy performance of multiple NZEHs is compared and analyzed. The data integrity is validated using various data sources. The findings can be referred to improve operations and future design of NZEHs. … (more)
- Is Part Of:
- Journal of cleaner production. Volume 172(2018)
- Journal:
- Journal of cleaner production
- Issue:
- Volume 172(2018)
- Issue Display:
- Volume 172, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 172
- Issue:
- 2018
- Issue Sort Value:
- 2018-0172-2018-0000
- Page Start:
- 106
- Page End:
- 118
- Publication Date:
- 2018-01-20
- Subjects:
- NetZero energy homes (NZEHs) -- Sensors -- Energy monitoring -- Energy performance
Factory and trade waste -- Management -- Periodicals
Manufactures -- Environmental aspects -- Periodicals
Déchets industriels -- Gestion -- Périodiques
Usines -- Aspect de l'environnement -- Périodiques
628.5 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09596526 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jclepro.2017.10.157 ↗
- Languages:
- English
- ISSNs:
- 0959-6526
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.369720
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21620.xml