Improved velocity‐selective‐inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition. Issue 5 (13th May 2020)
- Record Type:
- Journal Article
- Title:
- Improved velocity‐selective‐inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition. Issue 5 (13th May 2020)
- Main Title:
- Improved velocity‐selective‐inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition
- Authors:
- Liu, Dapeng
Xu, Feng
Li, Wenbo
van Zijl, Peter C.
Lin, Doris D.
Qin, Qin - Abstract:
- Abstract : Purpose: To further optimize the velocity‐selective arterial spin labeling (VSASL) sequence utilizing a Fourier‐transform based velocity‐selective inversion (FT‐VSI) pulse train, and to evaluate its utility for 3D mapping of cerebral blood flow (CBF) with a gradient‐ and spin‐echo (GRASE) readout. Methods: First, numerical simulations and phantom experiments were done to test the susceptibility to eddy currents and B1 field inhomogeneities for FT‐VSI pulse trains with block and composite refocusing pulses. Second, the choices of the post‐labeling delay (PLD) for FT‐VSI prepared 3D VSASL were evaluated for the sensitivity to perfusion signal. The study was conducted among a young‐age and a middle‐age group at 3T. Both signal‐to‐noise ratio (SNR) and CBF were quantitatively compared with pseudo‐continuous ASL (PCASL). The optimized 3D VSI‐ASL was also qualitatively compared with PCASL in a whole‐brain coverage among two healthy volunteers and a brain tumor patient. Results: The simulations and phantom test showed that composite refocusing pulses are more robust to both eddy‐currents and B1 field inhomogeneities than block pulses. 3D VSASL images with FT‐VSI preparation were acquired over a range of PLDs and PLD = 1.2 s was selected for its higher perfusion signal. FT‐VSI labeling produced quantitative CBF maps with 27% higher SNR in gray matter compared to PCASL. 3D whole‐brain CBF mapping using VSI‐ASL were comparable to the corresponding PCASL results. Conclusion:Abstract : Purpose: To further optimize the velocity‐selective arterial spin labeling (VSASL) sequence utilizing a Fourier‐transform based velocity‐selective inversion (FT‐VSI) pulse train, and to evaluate its utility for 3D mapping of cerebral blood flow (CBF) with a gradient‐ and spin‐echo (GRASE) readout. Methods: First, numerical simulations and phantom experiments were done to test the susceptibility to eddy currents and B1 field inhomogeneities for FT‐VSI pulse trains with block and composite refocusing pulses. Second, the choices of the post‐labeling delay (PLD) for FT‐VSI prepared 3D VSASL were evaluated for the sensitivity to perfusion signal. The study was conducted among a young‐age and a middle‐age group at 3T. Both signal‐to‐noise ratio (SNR) and CBF were quantitatively compared with pseudo‐continuous ASL (PCASL). The optimized 3D VSI‐ASL was also qualitatively compared with PCASL in a whole‐brain coverage among two healthy volunteers and a brain tumor patient. Results: The simulations and phantom test showed that composite refocusing pulses are more robust to both eddy‐currents and B1 field inhomogeneities than block pulses. 3D VSASL images with FT‐VSI preparation were acquired over a range of PLDs and PLD = 1.2 s was selected for its higher perfusion signal. FT‐VSI labeling produced quantitative CBF maps with 27% higher SNR in gray matter compared to PCASL. 3D whole‐brain CBF mapping using VSI‐ASL were comparable to the corresponding PCASL results. Conclusion: FT‐VSI with 3D‐GRASE readout was successfully implemented and showed higher sensitivity to perfusion signal than PCASL for both young and middle‐aged healthy volunteers. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 5(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 5(2020)
- Issue Display:
- Volume 84, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 5
- Issue Sort Value:
- 2020-0084-0005-0000
- Page Start:
- 2512
- Page End:
- 2522
- Publication Date:
- 2020-05-13
- Subjects:
- 3D GRASE acquisition -- arterial spin labeling -- cerebral blood flow -- velocity‐selective inversion
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28310 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21608.xml