Efficacy of the spiral flow generating extended tube during paediatric CCTA. Issue 2 (May 2022)
- Record Type:
- Journal Article
- Title:
- Efficacy of the spiral flow generating extended tube during paediatric CCTA. Issue 2 (May 2022)
- Main Title:
- Efficacy of the spiral flow generating extended tube during paediatric CCTA
- Authors:
- Masuda, T.
Funama, Y.
Nakaura, T.
Sato, T.
Tahara, M.
Yamashita, Y.
Yoshiura, T.
Masuda, S.
Gotanda, R.
Arao, K.
Imaizumi, H.
Arao, S.
Hiratsuka, J.
Awai, K. - Abstract:
- Abstract: Introduction: To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula. Methods: In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups. Results: There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than thoseAbstract: Introduction: To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula. Methods: In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups. Results: There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than those in the T-tube group (p < 0.05). Conclusion: The spiral-tube proved to be beneficial in improving the CT number for the AAO and PA, CNR, and visualisation score compared with the conventional T-tube during paediatric CCTA. Implications for practice: The spiral-tube may allow the visualisation of smaller blood vessels than those visualised by the conventional T-tube for paediatric patients in CCTA. … (more)
- Is Part Of:
- Radiography. Volume 28:Issue 2(2022)
- Journal:
- Radiography
- Issue:
- Volume 28:Issue 2(2022)
- Issue Display:
- Volume 28, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 28
- Issue:
- 2
- Issue Sort Value:
- 2022-0028-0002-0000
- Page Start:
- 420
- Page End:
- 425
- Publication Date:
- 2022-05
- Subjects:
- Computed tomography -- Contrast enhancement -- Paediatric -- Congenital heart disease -- Spiral flow-generating tube
Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2021.10.007 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21603.xml