Validation of the classification of surgically treated acetabular fractures in the Swedish Fracture Register. Issue 6 (June 2022)
- Record Type:
- Journal Article
- Title:
- Validation of the classification of surgically treated acetabular fractures in the Swedish Fracture Register. Issue 6 (June 2022)
- Main Title:
- Validation of the classification of surgically treated acetabular fractures in the Swedish Fracture Register
- Authors:
- Albrektsson, Madelene
Wolf, Olof
Enocson, Anders
Sundfeldt, Mikael - Abstract:
- Highlights: The accuracy of acetabular fracture classifications in the SFR was moderate and comparable to previous studies from the SFR on other fracture types. As the accuracy differed between fracture groups, care should be taken when analyzing data from the SFR on specific acetabular fracture groups. The intrarater agreement was substantial to almost perfect and interrater agreement was moderate to substantial. Abstract: Objectives: To validate the classification of surgically treated acetabular fractures in the Swedish Fracture Register (SFR) and to investigate the intra- and interrater reliability of the Judet-Letournel / AO/OTA classification systems. Methods: Surgically treated acetabular fractures were randomly selected from the SFR ( n = 132) and 124 fractures were classified independently by three experienced orthopedic pelvic surgeons at two different occasions. A gold standard classification was established for each case after these two sessions or, if necessary, after a discussion session. The gold standard classification was compared to the registered SFR classification to assess the validity of SFR data. Accuracy and intra- and interrater agreement were evaluated using Cohen´s kappa with interpretation according to Landis and Koch. Results: There was moderate agreement between the established gold standard classification and the SFR (kappa 0.43). The level of agreement differed between classification groups. The intrarater agreement was substantial to almostHighlights: The accuracy of acetabular fracture classifications in the SFR was moderate and comparable to previous studies from the SFR on other fracture types. As the accuracy differed between fracture groups, care should be taken when analyzing data from the SFR on specific acetabular fracture groups. The intrarater agreement was substantial to almost perfect and interrater agreement was moderate to substantial. Abstract: Objectives: To validate the classification of surgically treated acetabular fractures in the Swedish Fracture Register (SFR) and to investigate the intra- and interrater reliability of the Judet-Letournel / AO/OTA classification systems. Methods: Surgically treated acetabular fractures were randomly selected from the SFR ( n = 132) and 124 fractures were classified independently by three experienced orthopedic pelvic surgeons at two different occasions. A gold standard classification was established for each case after these two sessions or, if necessary, after a discussion session. The gold standard classification was compared to the registered SFR classification to assess the validity of SFR data. Accuracy and intra- and interrater agreement were evaluated using Cohen´s kappa with interpretation according to Landis and Koch. Results: There was moderate agreement between the established gold standard classification and the SFR (kappa 0.43). The level of agreement differed between classification groups. The intrarater agreement was substantial to almost perfect and interrater agreement was moderate to substantial. Conclusions: The accuracy of acetabular fracture classifications in the SFR was moderate and comparable to previous validation studies from the SFR on other fracture types. As the accuracy differed between fracture groups, care should be taken when analyzing data from the SFR on specific acetabular fracture groups. … (more)
- Is Part Of:
- Injury. Volume 53:Issue 6(2022)
- Journal:
- Injury
- Issue:
- Volume 53:Issue 6(2022)
- Issue Display:
- Volume 53, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 53
- Issue:
- 6
- Issue Sort Value:
- 2022-0053-0006-0000
- Page Start:
- 2145
- Page End:
- 2149
- Publication Date:
- 2022-06
- Subjects:
- Acetabular fractures -- Classification -- Validation -- Swedish Fracture Register -- Accuracy -- Reliability -- Intra- and interrater agreement
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2022.03.002 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21577.xml