Accurate reconstruction of bone defects in orbital–maxillary–zygomatic (OMZ) complex with polyetheretherketone (PEEK). Issue 5 (May 2022)
- Record Type:
- Journal Article
- Title:
- Accurate reconstruction of bone defects in orbital–maxillary–zygomatic (OMZ) complex with polyetheretherketone (PEEK). Issue 5 (May 2022)
- Main Title:
- Accurate reconstruction of bone defects in orbital–maxillary–zygomatic (OMZ) complex with polyetheretherketone (PEEK)
- Authors:
- Lv, Mingming
Yang, Xin
Gvetadze, Shalva R.
Gupta, Anand
Li, Jun
Sun, Jian - Abstract:
- Summary: Purpose: The aim of this study was to evaluate the safety and efficacy of using patient-specific polyetheretherketone (PEEK) for the reconstruction of patients with defects in orbital–maxillary–zygomatic (OMZ) complex. Patients and Methods: This study included 12 patients who underwent primary/delayed reconstruction of defects in OMZ complex by using patient-specific PEEK implants. Postoperative appearance (facial and orbital symmetry) and function were assessed after 6 months. Ophthalmologic examinations including globe position, exophthalmos, and orbital volume measurement were also performed. A comparative analysis of the treatment outcomes between pre- and postoperation was performed, and a value of P < 0.05 was considered as significant. Results: All patients underwent planned surgical procedure successfully. No obvious complications occurred. Facial symmetry and globe position were improved after surgery and the postoperative esthetic assessment was rated as excellent. The postoperative evaluation revealed that exophthalmos was 15.91 ± 1.80 mm, vertical position difference of eyeball 15.91 ± 1.80 mm, and orbital volume 15.91 ± 1.80 mm, respectively. There was a statistically significant difference in the mean values of exophthalmos, vertical position difference, and orbital volume among pre- and postoperation conditions, whereas there was no statistically significant difference between the reconstructed side and the unaffected side after surgery. Conclusion:Summary: Purpose: The aim of this study was to evaluate the safety and efficacy of using patient-specific polyetheretherketone (PEEK) for the reconstruction of patients with defects in orbital–maxillary–zygomatic (OMZ) complex. Patients and Methods: This study included 12 patients who underwent primary/delayed reconstruction of defects in OMZ complex by using patient-specific PEEK implants. Postoperative appearance (facial and orbital symmetry) and function were assessed after 6 months. Ophthalmologic examinations including globe position, exophthalmos, and orbital volume measurement were also performed. A comparative analysis of the treatment outcomes between pre- and postoperation was performed, and a value of P < 0.05 was considered as significant. Results: All patients underwent planned surgical procedure successfully. No obvious complications occurred. Facial symmetry and globe position were improved after surgery and the postoperative esthetic assessment was rated as excellent. The postoperative evaluation revealed that exophthalmos was 15.91 ± 1.80 mm, vertical position difference of eyeball 15.91 ± 1.80 mm, and orbital volume 15.91 ± 1.80 mm, respectively. There was a statistically significant difference in the mean values of exophthalmos, vertical position difference, and orbital volume among pre- and postoperation conditions, whereas there was no statistically significant difference between the reconstructed side and the unaffected side after surgery. Conclusion: With the aid of virtual surgical planning and individual custom-made surgical guides, patient-specific PEEK implantation can successfully reconstruct the complicated 3D structure of OMZ complex and shows excellent biocompatibility and clinical outcomes. … (more)
- Is Part Of:
- Journal of plastic, reconstructive & aesthetic surgery. Volume 75:Issue 5(2022)
- Journal:
- Journal of plastic, reconstructive & aesthetic surgery
- Issue:
- Volume 75:Issue 5(2022)
- Issue Display:
- Volume 75, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 75
- Issue:
- 5
- Issue Sort Value:
- 2022-0075-0005-0000
- Page Start:
- 1750
- Page End:
- 1757
- Publication Date:
- 2022-05
- Subjects:
- Patient-specific implant (PSI) -- Polyetheretherketone (PEEK) -- Orbital–maxillary–zygomatic (OMZ) complex -- Computer-aided design/computer-assisted manufacturing (CAD/CAM) -- Virtual surgical planning (VSP)
Surgery, Plastic -- Great Britain -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Great Britain -- Periodicals
617.9505 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17486815 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.bjps.2021.11.101 ↗
- Languages:
- English
- ISSNs:
- 1748-6815
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5040.695800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21572.xml