Comparison of extraction‐based and elution‐based polymerase chain reaction testing, and automated and rapid antigen testing for the diagnosis of severe acute respiratory syndrome coronavirus 2. Issue 7 (22nd March 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of extraction‐based and elution‐based polymerase chain reaction testing, and automated and rapid antigen testing for the diagnosis of severe acute respiratory syndrome coronavirus 2. Issue 7 (22nd March 2022)
- Main Title:
- Comparison of extraction‐based and elution‐based polymerase chain reaction testing, and automated and rapid antigen testing for the diagnosis of severe acute respiratory syndrome coronavirus 2
- Authors:
- Yoshioka, Nori
Deguchi, Matsuo
Hagiya, Hideharu
Kagita, Masanori
Tsukamoto, Hiroko
Takao, Miyuki
Yoshida, Hisao
Hamaguchi, Shigeto
Maeda, Ikuhiro
Hidaka, Yoh
Tomono, Kazunori - Abstract:
- Abstract: We aimed to compare the differences in testing performance of extraction‐based polymerase chain reaction (PCR) assays, elution‐based direct PCR assay, and rapid antigen detection tests for severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2). We used nasopharyngeal swab samples of patients with coronavirus disease 2019 (COVID‐19). We used the MagNA Pure 24 System (Roche Diagnostics K.K.) or magLEAD 12gC (Precision System Science Co., Ltd.) for RNA extraction, mixed the concentrates with either the LightMix Modular SARS‐CoV PCR mixture (Roche Diagnostics K.K.) or Takara SARS‐CoV‐2 direct PCR detection kit (Takara Bio Inc.), and amplified it using COBAS® z480 (Roche Diagnostics K.K.). For elution‐based PCR, we directly applied clinical samples to the Takara SARS‐CoV‐2 direct PCR detection kit before the same amplification step. Additionally, we performed Espline SARS‐CoV‐2 (Fuji Rebio Co., Ltd.) for rapid diagnostic test (RDT), and used Lumipulse SARS‐CoV‐2 antigen (Fuji Rebio Co., Ltd.) and Elecsys SARS‐CoV‐2 antigen (Roche Diagnostics K.K.) for automated antigen tests (ATs). Extraction‐based and elution‐based PCR tests detected the virus up to 214–216 and 210 times dilution, respectively. ATs remained positive up to 24–26 times dilution, while RDT became negative after 22 dilutions. For 153 positive samples, positivity rates of the extraction‐based PCR assay were 85.6% to 98.0%, while that of the elution‐based PCR assay was 73.2%. Based on the RNAAbstract: We aimed to compare the differences in testing performance of extraction‐based polymerase chain reaction (PCR) assays, elution‐based direct PCR assay, and rapid antigen detection tests for severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2). We used nasopharyngeal swab samples of patients with coronavirus disease 2019 (COVID‐19). We used the MagNA Pure 24 System (Roche Diagnostics K.K.) or magLEAD 12gC (Precision System Science Co., Ltd.) for RNA extraction, mixed the concentrates with either the LightMix Modular SARS‐CoV PCR mixture (Roche Diagnostics K.K.) or Takara SARS‐CoV‐2 direct PCR detection kit (Takara Bio Inc.), and amplified it using COBAS® z480 (Roche Diagnostics K.K.). For elution‐based PCR, we directly applied clinical samples to the Takara SARS‐CoV‐2 direct PCR detection kit before the same amplification step. Additionally, we performed Espline SARS‐CoV‐2 (Fuji Rebio Co., Ltd.) for rapid diagnostic test (RDT), and used Lumipulse SARS‐CoV‐2 antigen (Fuji Rebio Co., Ltd.) and Elecsys SARS‐CoV‐2 antigen (Roche Diagnostics K.K.) for automated antigen tests (ATs). Extraction‐based and elution‐based PCR tests detected the virus up to 214–216 and 210 times dilution, respectively. ATs remained positive up to 24–26 times dilution, while RDT became negative after 22 dilutions. For 153 positive samples, positivity rates of the extraction‐based PCR assay were 85.6% to 98.0%, while that of the elution‐based PCR assay was 73.2%. Based on the RNA concentration process, extraction‐based PCR assays were superior to elution‐based direct PCR assays for detecting SARS‐CoV‐2. … (more)
- Is Part Of:
- Journal of medical virology. Volume 94:Issue 7(2022)
- Journal:
- Journal of medical virology
- Issue:
- Volume 94:Issue 7(2022)
- Issue Display:
- Volume 94, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 94
- Issue:
- 7
- Issue Sort Value:
- 2022-0094-0007-0000
- Page Start:
- 3155
- Page End:
- 3159
- Publication Date:
- 2022-03-22
- Subjects:
- novel coronavirus disease 2019 (COVID‐19) -- polymerase chain reaction -- rapid diagnostic test -- severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2)
Virology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1096-9071 ↗
http://www.interscience.wiley.com/jpages/0146-6615 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmv.27709 ↗
- Languages:
- English
- ISSNs:
- 0146-6615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21567.xml