Implementing and evaluating a high‐resolution diode array for patient‐specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy. Issue 5 (12th March 2022)
- Record Type:
- Journal Article
- Title:
- Implementing and evaluating a high‐resolution diode array for patient‐specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy. Issue 5 (12th March 2022)
- Main Title:
- Implementing and evaluating a high‐resolution diode array for patient‐specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy
- Authors:
- Xu, Qianyi
Huynh, Kiet
Nie, Wei
Rose, Mark S.
Chawla, Ashish K.
Choe, Kevin S.
Kanani, Samir
Kubicek, Gregory J.
Fan, Jiajin - Abstract:
- Abstract: The purpose of the study was to introduce and evaluate a high‐resolution diode array for patient‐specific quality assurance (PSQA) of CyberKnife brain stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). Thirty‐three intracranial plans were retrospectively delivered on the SRS MapCHECK using fixed cone, Iris, and multileaf collimator (MLC). The plans were selected to cover a range of sites from large tumor bed, single/multiple small brain metastases (METs) to trigeminal neuralgia. Fiducial tracking using the four fiducials embedded around the detector plane was used as image guidance. Results were analyzed before and after registration based on absolute dose gamma criterion of 1 mm distance‐to‐agreement and 0.5%–3% dose‐difference. Overall, the gamma passing rates (1 mm and 3% criterion) before registration for all the patients were above 90% for all three treatment modalities (96.8 ± 3.5%, the lowest passing rate of 90.4%), and were improved after registration (99.3 ± 1.5%). When tighter criteria (1 mm and 2%) were applied, the gamma passing rates after registration for all the cases dropped to 97.3 ± 3.2%. For trigeminal neuralgia cases, we applied 1 mm and 0.5% criterion and the passing rates dropped from 100 ± 0.0% to 98.5 ± 2.0%. The mean delivery time was 33.4 ± 11.7 min, 24.0 ± 4.9 min, and 17.1 ± 2.6 min for the fixed cone, Iris, and MLC, respectively. With superior gamma passing rates and reasonable quality assurance (QA) time, we believeAbstract: The purpose of the study was to introduce and evaluate a high‐resolution diode array for patient‐specific quality assurance (PSQA) of CyberKnife brain stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). Thirty‐three intracranial plans were retrospectively delivered on the SRS MapCHECK using fixed cone, Iris, and multileaf collimator (MLC). The plans were selected to cover a range of sites from large tumor bed, single/multiple small brain metastases (METs) to trigeminal neuralgia. Fiducial tracking using the four fiducials embedded around the detector plane was used as image guidance. Results were analyzed before and after registration based on absolute dose gamma criterion of 1 mm distance‐to‐agreement and 0.5%–3% dose‐difference. Overall, the gamma passing rates (1 mm and 3% criterion) before registration for all the patients were above 90% for all three treatment modalities (96.8 ± 3.5%, the lowest passing rate of 90.4%), and were improved after registration (99.3 ± 1.5%). When tighter criteria (1 mm and 2%) were applied, the gamma passing rates after registration for all the cases dropped to 97.3 ± 3.2%. For trigeminal neuralgia cases, we applied 1 mm and 0.5% criterion and the passing rates dropped from 100 ± 0.0% to 98.5 ± 2.0%. The mean delivery time was 33.4 ± 11.7 min, 24.0 ± 4.9 min, and 17.1 ± 2.6 min for the fixed cone, Iris, and MLC, respectively. With superior gamma passing rates and reasonable quality assurance (QA) time, we believe the SRS MapCHECK could be a good option for routine PSQA for CyberKnife SRS/SRT. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 5(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 5(2022)
- Issue Display:
- Volume 23, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2022-0023-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-03-12
- Subjects:
- CyberKnife -- diode array -- PSQA
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13569 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21570.xml