End to end comparison of surface‐guided imaging versus stereoscopic X‐rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel phantoms. Issue 5 (24th March 2022)
- Record Type:
- Journal Article
- Title:
- End to end comparison of surface‐guided imaging versus stereoscopic X‐rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel phantoms. Issue 5 (24th March 2022)
- Main Title:
- End to end comparison of surface‐guided imaging versus stereoscopic X‐rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel phantoms
- Authors:
- Bry, Victoria
Saenz, Daniel
Pappas, Evangelos
Kalaitzakis, Georgios
Papanikolaou, Nikos
Rasmussen, Karl - Abstract:
- Abstract: Introduction: Two end‐to‐end tests evaluate the accuracy of a surface‐guided radiation therapy (SGRT) system (CRAD Catalyst HD) for position verification in comparison to a stereoscopic x‐ray imaging system (Brainlab Exactrac ) for single‐isocenter, multiple metastases stereotactic radiosurgery (SRS) using 3D polymer gel inserts. Materials and methods: A 3D‐printed phantom (Prime phantom, RTsafe PC, Athens, Greece) with two separate cylindrical polymer gel inserts were immobilized in open‐face masks and treated with a single isocentric, multitarget SRS plan. Planning was done in Brainlab (Elements) to treat five metastatic lesions in one fraction, and initial setup was done using cone beam computed tomography. Positional verification was done using orthogonal X‐ray imaging (Brainlab Exactrac) and/or a surface imaging system (CRAD Catalyst HD, Uppsala, Sweden), and shift discrepancies were recorded for each couch angle. Forty‐two hours after irradiation, the gel phantom was scanned in a 1.5 Tesla MRI, and images were fused with the patient computed tomography data/structure set for further analysis of spatial dose distribution. Results: Discrepancies between the CRAD Catalyst HD system and Brainlab Exactrac were <1 mm in the translational direction and <0.5° in the angular direction at noncoplanar couch angles. Dose parameters ( D Mean%, D 95% ) and 3D gamma index passing rates were evaluated for both setup modalities for each planned target volume (PTV) at aAbstract: Introduction: Two end‐to‐end tests evaluate the accuracy of a surface‐guided radiation therapy (SGRT) system (CRAD Catalyst HD) for position verification in comparison to a stereoscopic x‐ray imaging system (Brainlab Exactrac ) for single‐isocenter, multiple metastases stereotactic radiosurgery (SRS) using 3D polymer gel inserts. Materials and methods: A 3D‐printed phantom (Prime phantom, RTsafe PC, Athens, Greece) with two separate cylindrical polymer gel inserts were immobilized in open‐face masks and treated with a single isocentric, multitarget SRS plan. Planning was done in Brainlab (Elements) to treat five metastatic lesions in one fraction, and initial setup was done using cone beam computed tomography. Positional verification was done using orthogonal X‐ray imaging (Brainlab Exactrac) and/or a surface imaging system (CRAD Catalyst HD, Uppsala, Sweden), and shift discrepancies were recorded for each couch angle. Forty‐two hours after irradiation, the gel phantom was scanned in a 1.5 Tesla MRI, and images were fused with the patient computed tomography data/structure set for further analysis of spatial dose distribution. Results: Discrepancies between the CRAD Catalyst HD system and Brainlab Exactrac were <1 mm in the translational direction and <0.5° in the angular direction at noncoplanar couch angles. Dose parameters ( D Mean%, D 95% ) and 3D gamma index passing rates were evaluated for both setup modalities for each planned target volume (PTV) at a variety of thresholds: 3%/2 mm (Exactrac≥93.1% and CRAD ≥87.2%), 5%/2 mm (Exactrac≥95.6% and CRAD ≥94.6%), and 5%/1 mm (Exactrac≥81.8% and CRAD ≥83.7%). Conclusion: Dose metrics for a setup with surface imaging was found to be consistent with setup using x‐ray imaging, demonstrating high accuracy and reproducibility for treatment delivery. Results indicate the feasibility of using surface imaging for position verification at noncoplanar couch angles for single‐isocenter, multiple‐target SRS using end‐to‐end quality assurance (QA) testing with 3D polymer gel dosimetry. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 5(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 5(2022)
- Issue Display:
- Volume 23, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2022-0023-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-03-24
- Subjects:
- C‐RAD Catalyst HD -- end to end -- immobilization -- open face masks -- Quality Assurance -- SGRT -- SRS -- stereotactic radiosurgery -- surface imaging
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13576 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21570.xml