Automatic 3D analysis of the ex-vivo porcine lumbar interbody fusion based on X-ray micro computed tomography data. (June 2022)
- Record Type:
- Journal Article
- Title:
- Automatic 3D analysis of the ex-vivo porcine lumbar interbody fusion based on X-ray micro computed tomography data. (June 2022)
- Main Title:
- Automatic 3D analysis of the ex-vivo porcine lumbar interbody fusion based on X-ray micro computed tomography data
- Authors:
- Laznovsky, Jakub
Brinek, Adam
Zikmund, Tomas
Boudova, Marketa
Vojtova, Lucy
Dorazilova, Jana
Trunec, Martin
Stastny, Premysl
Krticka, Milan
Planka, Ladislav
Ira, Daniel
Faldyna, Martin
Kaiser, Jozef - Abstract:
- Abstract: Spinal fusion is a surgical procedure used to join two or more vertebrae to prevent movement between them. This surgical procedure is considered in patients suffering from a wide range of degenerative spinal diseases or vertebral fractures. The success rate of spinal fusion is frequently evaluated subjectively using X-ray computed tomography. The pig was chosen as an animal model for spinal fusion, since its spinal structure is similar to the human spine. Our paper presents an automatic approach for pig's spinal fusion evaluation in 3D. The proposed approach is based on the determination of the vertebral fused area, which reflects the fusion quality. The approach was applied and tested on microCT (μCT) data of fused porcine vertebrae ex-vivo. In our study, three types of implants were used to perform spinal fusion: the iliac crest bone graft used as the gold standard, and two types of novel scaffold implants based on the polymer/ceramic porous foam involving either growth factors or polyphosphates. The evaluation worked automatically for all three types of used implants, and the fusion quality was determined quantitatively. The calculation is based on the detection of the fused area and area of facies intervertebralis, so the percentual representation of the vertebral joint can be determined. Since this approach is versatile and is described in detail as a guide for image processing the data of vertebrae fusion, this methodology has the potential to establish aAbstract: Spinal fusion is a surgical procedure used to join two or more vertebrae to prevent movement between them. This surgical procedure is considered in patients suffering from a wide range of degenerative spinal diseases or vertebral fractures. The success rate of spinal fusion is frequently evaluated subjectively using X-ray computed tomography. The pig was chosen as an animal model for spinal fusion, since its spinal structure is similar to the human spine. Our paper presents an automatic approach for pig's spinal fusion evaluation in 3D. The proposed approach is based on the determination of the vertebral fused area, which reflects the fusion quality. The approach was applied and tested on microCT (μCT) data of fused porcine vertebrae ex-vivo. In our study, three types of implants were used to perform spinal fusion: the iliac crest bone graft used as the gold standard, and two types of novel scaffold implants based on the polymer/ceramic porous foam involving either growth factors or polyphosphates. The evaluation worked automatically for all three types of used implants, and the fusion quality was determined quantitatively. The calculation is based on the detection of the fused area and area of facies intervertebralis, so the percentual representation of the vertebral joint can be determined. Since this approach is versatile and is described in detail as a guide for image processing the data of vertebrae fusion, this methodology has the potential to establish a standard approach for evaluating the fusion quality in ex-vivo samples that can be tested on clinical data. Graphical abstract: Image 1 Highlights: An automatic evaluation of spinal fusion process (no inaccuracies caused by the user). A robust algorithm which can objectively evaluate the quality of vertebrae fusion, after the Lumbar Interbody Fusion surgery. The result is presented as a single accurate number, representing how successfully have both vertebrae fused. The presented methodology is able to quickly compare the fusion quality in samples, where different types of intervertebral implants were used. The methodology is based on 3D microCT images with high resolution in order to analyse the fusion quality non-destructively. … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 145(2022)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 145(2022)
- Issue Display:
- Volume 145, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 145
- Issue:
- 2022
- Issue Sort Value:
- 2022-0145-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Vertebrae fusion -- Spinal fusion -- Computed tomography -- Image processing -- Regenerative medicine -- Lumbar spinal surgery
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2022.105438 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21569.xml