Onboard cone‐beam CT‐based replan evaluation for head and neck proton therapy. Issue 5 (7th February 2022)
- Record Type:
- Journal Article
- Title:
- Onboard cone‐beam CT‐based replan evaluation for head and neck proton therapy. Issue 5 (7th February 2022)
- Main Title:
- Onboard cone‐beam CT‐based replan evaluation for head and neck proton therapy
- Authors:
- Stanforth, Alexander
Lin, Liyong
Beitler, Jonathan J.
Janopaul‐Naylor, James R.
Chang, Chih‐Wei
Press, Robert H.
Patel, Sagar A.
Zhao, Jennifer
Eaton, Bree
Schreibmann, Eduard E.
Jung, James
Bohannon, Duncan
Liu, Tian
Yang, Xiaofeng
McDonald, Mark W.
Zhou, Jun - Abstract:
- Abstract: Purpose: Quality assurance computed tomography (QACT) is the current clinical practice in proton therapy to evaluate the needs for replan. QACT could falsely indicate replan because of setup issues that would be solved on the treatment machine. Deforming the treatment planning CT (TPCT) to the pretreatment CBCT may eliminate this issue. We investigated the performance of replan evaluation based on deformed TPCT (TPCTdir) for proton head and neck (H&N) therapy. Methods and materials: Twenty‐eight H&N datasets along with pretreatment CBCT and QACT were used to validate the method. The changes in body volume were analyzed between the no‐replan and replan groups. The dose on the TPCTdir, the deformed QACT (QACTdir), and the QACT were calculated by applying the clinical plans to these image sets. Dosimetric parameters' changes, including ΔD95, ΔDmean, and ΔD1 for the clinical target volumes (CTVs) were calculated. Receiver operating characteristic curves for replan evaluation based on ΔD95 on QACT and TPCTdir were calculated, using ΔD95 on QACTdir as the reference. A threshold for replan based on ΔD95 on TPCTdir is proposed. The specificities for the proposed method were calculated. Results: The changes in the body contour were 95.8 ± 83.8 cc versus 305.0 ± 235.0 cc ( p < 0.01) for the no‐replan and replan groups, respectively. The ΔD95, ΔDmean, and ΔD1 are all comparable for all the evaluations. The differences between TPCTdir and QACTdir evaluations were 0.30% ±Abstract: Purpose: Quality assurance computed tomography (QACT) is the current clinical practice in proton therapy to evaluate the needs for replan. QACT could falsely indicate replan because of setup issues that would be solved on the treatment machine. Deforming the treatment planning CT (TPCT) to the pretreatment CBCT may eliminate this issue. We investigated the performance of replan evaluation based on deformed TPCT (TPCTdir) for proton head and neck (H&N) therapy. Methods and materials: Twenty‐eight H&N datasets along with pretreatment CBCT and QACT were used to validate the method. The changes in body volume were analyzed between the no‐replan and replan groups. The dose on the TPCTdir, the deformed QACT (QACTdir), and the QACT were calculated by applying the clinical plans to these image sets. Dosimetric parameters' changes, including ΔD95, ΔDmean, and ΔD1 for the clinical target volumes (CTVs) were calculated. Receiver operating characteristic curves for replan evaluation based on ΔD95 on QACT and TPCTdir were calculated, using ΔD95 on QACTdir as the reference. A threshold for replan based on ΔD95 on TPCTdir is proposed. The specificities for the proposed method were calculated. Results: The changes in the body contour were 95.8 ± 83.8 cc versus 305.0 ± 235.0 cc ( p < 0.01) for the no‐replan and replan groups, respectively. The ΔD95, ΔDmean, and ΔD1 are all comparable for all the evaluations. The differences between TPCTdir and QACTdir evaluations were 0.30% ± 0.86%, 0.00 ± 0.22 Gy, and −0.17 ± 0.61 Gy for CTV ΔD95, ΔDmean, and ΔD1, respectively. The corresponding differences between the QACT and QACTdir were 0.12% ± 1.1%, 0.02 ± 0.32 Gy, and −0.01 ± 0.71 Gy. CTV ΔD95 > 2.6% in TPCTdir was chosen as the threshold to trigger QACT/replan. The corresponding specificity was 94% and 98% for the clinical practice and the proposed method, respectively. Conclusions: The replan evaluation based on TPCTdir provides better specificity than that based on the QACT. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 5(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 5(2022)
- Issue Display:
- Volume 23, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2022-0023-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-02-07
- Subjects:
- adaptive proton therapy -- CBCT -- deformable registration -- ROC
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13550 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21570.xml