Different precompression does not reduce the diagnostic value of virtual touch tissue imaging and quantification (VTIQ) in breast lesions, especially for the ratio of the shear wave velocity between lesions and surrounding tissues. Issue 151 (June 2022)
- Record Type:
- Journal Article
- Title:
- Different precompression does not reduce the diagnostic value of virtual touch tissue imaging and quantification (VTIQ) in breast lesions, especially for the ratio of the shear wave velocity between lesions and surrounding tissues. Issue 151 (June 2022)
- Main Title:
- Different precompression does not reduce the diagnostic value of virtual touch tissue imaging and quantification (VTIQ) in breast lesions, especially for the ratio of the shear wave velocity between lesions and surrounding tissues
- Authors:
- Wang, Achen
Zhong, Jingwen
Wang, Shuhan
Wang, Hongbo
Tao, Lin
Wei, Hong
Chen, Xi
Zhou, Xianli
Sun, Jiawei - Abstract:
- Highlights: Shear wave elastography were used to evaluate breast lesions at different precompression. Diagnostic parameters included the lesion-to-surrounding tissues shear wave velocity ratios. Precompression does increase the stiffness of breast lesions, fat and gland tissues. Abstract: Objective: To investigate the accuracy of virtual touch tissue imaging and quantification (VTIQ) in the diagnosis of benign and malignant breast lesions under four different precompression levels. The shear wave velocity (SWV) ratios of lesion to surrounding tissue were also added for diagnosis. Methods: 167 female patients with breast lesions were included in this single center prospective study. VTIQ was performed under four different precompression levels. The SWV of the lesion, surrounding fat, and gland tissue were measured at the same depth as much as feasible 7 times. The breast lesions studied were all histopathologically confirmed. The VTIQ parameters were compared between precompression levels. The area under the receiver operating characteristic curve (AUC) was calculated to evaluate the diagnostic performance of each parameter of the VTIQ. Results: The VTIQ parameters of the malignant lesions were significantly higher than those of benign lesions in all precompression levels (P < 0.001). SWV of the lesion, fat, and gland tissue increased significantly with increasing precompression. The VTIQ parameters had great diagnostic performance for breast lesions in all precompressionHighlights: Shear wave elastography were used to evaluate breast lesions at different precompression. Diagnostic parameters included the lesion-to-surrounding tissues shear wave velocity ratios. Precompression does increase the stiffness of breast lesions, fat and gland tissues. Abstract: Objective: To investigate the accuracy of virtual touch tissue imaging and quantification (VTIQ) in the diagnosis of benign and malignant breast lesions under four different precompression levels. The shear wave velocity (SWV) ratios of lesion to surrounding tissue were also added for diagnosis. Methods: 167 female patients with breast lesions were included in this single center prospective study. VTIQ was performed under four different precompression levels. The SWV of the lesion, surrounding fat, and gland tissue were measured at the same depth as much as feasible 7 times. The breast lesions studied were all histopathologically confirmed. The VTIQ parameters were compared between precompression levels. The area under the receiver operating characteristic curve (AUC) was calculated to evaluate the diagnostic performance of each parameter of the VTIQ. Results: The VTIQ parameters of the malignant lesions were significantly higher than those of benign lesions in all precompression levels (P < 0.001). SWV of the lesion, fat, and gland tissue increased significantly with increasing precompression. The VTIQ parameters had great diagnostic performance for breast lesions in all precompression levels (AUC = 0.765–0.911). There was no significant difference between the precompression levels of the lesion-to-fat SWV ratio and the lesion-to-gland SWV ratio in benign and malignant lesions, and the cut-off coefficients of variation were 7.42% and 8.55%, respectively. Conclusions: Precompression can increase the stiffness of breast lesions, fat and gland tissues, but does not reduce diagnostic value of VTIQ parameters in the breast. Under different precompression levels, the diagnosis of breast lesions by the ratio of the SWV of the lesion to the surrounding tissues is more stable. … (more)
- Is Part Of:
- European journal of radiology. Issue 151(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 151(2022)
- Issue Display:
- Volume 151, Issue 151 (2022)
- Year:
- 2022
- Volume:
- 151
- Issue:
- 151
- Issue Sort Value:
- 2022-0151-0151-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Elastography -- Breast lesion -- Precompression
ARFI Acoustic radiation force impulse -- AUC Area under the ROC curves -- CUS Conventional ultrasound -- CV Coefficient of variation -- ICC Intraclass correlation coefficient -- LR Likelihood ratio -- NPV Negative predictive value -- PPV Positive predictive value -- QM Quality mode -- ROC Receiver operating characteristic -- ROI Regions of interest -- SD Standard deviation -- SE Strain elastography -- SWE Shear wave elastography -- SWV Shear wave velocity -- SWV-F Mean SWV of fat -- SWV-G Mean SWV of gland -- SWV-L/F Lesion-to-fat SWV ratio -- SWV-L/G Lesion-to-gland SWV ratio -- SWV-max Maximum SWV -- SWV-mean Mean SWV -- SWV-min Minimum SWV -- US Ultrasound -- VTIQ Virtual touch tissue imaging and quantification
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110284 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21539.xml