Ultra-rapid flow cytometry assay for colistin MIC determination in Enterobacterales, Pseudomonas aeruginosa and Acinetobacter baumannii. (November 2020)
- Record Type:
- Journal Article
- Title:
- Ultra-rapid flow cytometry assay for colistin MIC determination in Enterobacterales, Pseudomonas aeruginosa and Acinetobacter baumannii. (November 2020)
- Main Title:
- Ultra-rapid flow cytometry assay for colistin MIC determination in Enterobacterales, Pseudomonas aeruginosa and Acinetobacter baumannii
- Authors:
- Fonseca e Silva, Daniela
Andrade, Ferdinando F.
Gomes, Rosário
Silva-Dias, Ana
Martins-Oliveira, Inês
Pérez-Viso, Blanca
Ramos, Maria Helena
Rodrigues, Acácio G.
Cantón, Rafael
Pina-Vaz, Cidália - Abstract:
- Abstract: Objectives: Both EUCAST and CLSI recommend broth microdilution for antimicrobial susceptibility testing of colistin, but this method is cumbersome and takes 16-24 h to give results. Our objective was to evaluate a rapid quantitative colistin MIC susceptibility assay based on flow cytometry analysis (FASTcolistin MIC) in comparison with standard broth microdilution assay. Methods: One hundred and sixteen Gram-negative bacilli (78 Enterobacterales, 28 Pseudomonas aeruginosa and 10 Acinetobacter baumannii) were studied in parallel using standard broth microdilution following EUCAST recommendations and FASTcolistin MIC kit. In the last one, a bacteria suspension (0.5 MacFarland) was prepared, diluted in Muller-Hinton broth, incubated in the susceptibility panel containing different colistin concentrations (range 0.125-64 mg/L) with a fluorescent probe and incubated 1 h at 35ºC. After that, a flow cytometry analysis using CytoFLEX (Beckmam) was performed. Using a dedicated software (BioFAST) an automated MIC result was obtained after 1.5 h. Performance evaluation was performed according to the ISO standard 20776-2. Reproducibility and repeatability, categorical (CA) and essential agreement (EA), and lot-to-lot variation and operator-to-operator variability, as well as time to results were determined. Results: Overall, 100% CA (CI 97-100%) and 95.7% EA (CI 90-98%) was obtained with high repeatability (100%; CI 80-100%)and reproducibility (97%; (CI 83-99%)). Absence ofAbstract: Objectives: Both EUCAST and CLSI recommend broth microdilution for antimicrobial susceptibility testing of colistin, but this method is cumbersome and takes 16-24 h to give results. Our objective was to evaluate a rapid quantitative colistin MIC susceptibility assay based on flow cytometry analysis (FASTcolistin MIC) in comparison with standard broth microdilution assay. Methods: One hundred and sixteen Gram-negative bacilli (78 Enterobacterales, 28 Pseudomonas aeruginosa and 10 Acinetobacter baumannii) were studied in parallel using standard broth microdilution following EUCAST recommendations and FASTcolistin MIC kit. In the last one, a bacteria suspension (0.5 MacFarland) was prepared, diluted in Muller-Hinton broth, incubated in the susceptibility panel containing different colistin concentrations (range 0.125-64 mg/L) with a fluorescent probe and incubated 1 h at 35ºC. After that, a flow cytometry analysis using CytoFLEX (Beckmam) was performed. Using a dedicated software (BioFAST) an automated MIC result was obtained after 1.5 h. Performance evaluation was performed according to the ISO standard 20776-2. Reproducibility and repeatability, categorical (CA) and essential agreement (EA), and lot-to-lot variation and operator-to-operator variability, as well as time to results were determined. Results: Overall, 100% CA (CI 97-100%) and 95.7% EA (CI 90-98%) was obtained with high repeatability (100%; CI 80-100%)and reproducibility (97%; (CI 83-99%)). Absence of lot-to-lot variations or differences in the operators' performance was observed. Conclusions: FASTcolistin MIC is an accurate, reliable and ultra-rapid method (1 h incubation versus 24 h) for susceptibility testing of colistin of common Gram-negative bacilli recovered in clinical laboratories. … (more)
- Is Part Of:
- Clinical microbiology and infection. Volume 26:Number 11(2020)
- Journal:
- Clinical microbiology and infection
- Issue:
- Volume 26:Number 11(2020)
- Issue Display:
- Volume 26, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 26
- Issue:
- 11
- Issue Sort Value:
- 2020-0026-0011-0000
- Page Start:
- 1559.e1
- Page End:
- 1559.e4
- Publication Date:
- 2020-11
- Subjects:
- Antibiotic susceptibility -- AST -- Colistin -- Flow-cytometry -- MDR microorganisms -- MIC determination -- Microdilution
Medical microbiology -- Periodicals
Diagnostic microbiology -- Periodicals
Communicable diseases -- Periodicals
Infection -- Periodicals
616.01 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1469-0691 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.cmi.2020.08.019 ↗
- Languages:
- English
- ISSNs:
- 1198-743X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.305520
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21546.xml