New ultra-fast algorithm for cochlear implant misalignment detection. Issue 151 (June 2022)
- Record Type:
- Journal Article
- Title:
- New ultra-fast algorithm for cochlear implant misalignment detection. Issue 151 (June 2022)
- Main Title:
- New ultra-fast algorithm for cochlear implant misalignment detection
- Authors:
- Waldeck, Stephan
Helal, Rania
Al-Dhamari, Ibraheem
Schmidt, Sandra
von Falck, Christian
Chapot, René
Brockmann, Marc
Overhoff, Daniel - Abstract:
- Highlights: A new ultra-fast algorithm for segmentation of the cochlea after CI implantation reduces the time for analyzing misalignment of the electrode significantly. Readers of different experience levels benefit equally from the new ultra-fast algorithm. Postoperative multiplanar CBCT/ CT imaging after CI implantation reveals higher incidence of misalignement as indicated by recent literature. Abstract: Purpose: Postoperative imaging following cochlear implant (CI) placement is currently the only means of diagnosing proper electrode position. Manual multiplanar reconstruction (MPR) analysis of CT and CBCT is time-consuming and requires extensive training. This study aims to evaluate the rate of CI misalignment and to determine the amount of time necessary to reach a diagnosis of correct versus incorrect CI placement for readers of different experience levels, using a novel algorithm for image analysis (ACIR) compared to MPR analysis. Method: The retrospective single centre study included 333 patients with cochlear implant surgery between May 2002 and May 2021. Postoperative CT and CBCT images were evaluated in three subgroups and the time to diagnosis was documented. Group 1: image evaluation using conventional MPR analysis; group 2: image evaluation by an experienced neuroradiologist via a novel ultra-fast algorithm; group 3: image evaluation by a young specialist via novel ultra-fast algorithm. T-test and Pearson's chi-squared test were used for inter-groupHighlights: A new ultra-fast algorithm for segmentation of the cochlea after CI implantation reduces the time for analyzing misalignment of the electrode significantly. Readers of different experience levels benefit equally from the new ultra-fast algorithm. Postoperative multiplanar CBCT/ CT imaging after CI implantation reveals higher incidence of misalignement as indicated by recent literature. Abstract: Purpose: Postoperative imaging following cochlear implant (CI) placement is currently the only means of diagnosing proper electrode position. Manual multiplanar reconstruction (MPR) analysis of CT and CBCT is time-consuming and requires extensive training. This study aims to evaluate the rate of CI misalignment and to determine the amount of time necessary to reach a diagnosis of correct versus incorrect CI placement for readers of different experience levels, using a novel algorithm for image analysis (ACIR) compared to MPR analysis. Method: The retrospective single centre study included 333 patients with cochlear implant surgery between May 2002 and May 2021. Postoperative CT and CBCT images were evaluated in three subgroups and the time to diagnosis was documented. Group 1: image evaluation using conventional MPR analysis; group 2: image evaluation by an experienced neuroradiologist via a novel ultra-fast algorithm; group 3: image evaluation by a young specialist via novel ultra-fast algorithm. T-test and Pearson's chi-squared test were used for inter-group comparisons. Results: 333 patients (63.3 ± 15.9 years; 188 men) with 335 CIs were evaluated. The rate of CI misalignment diagnosed from 3D imaging was 14.3% (n = 48). MPR analysis required 255.7 ± 70.4 s per temporal bone, whereas Slicer plugin reduced analysis time to 83.3 ± 7.7 s (p < 0.001) for the experienced reader and 89.6 ± 8.7 s for the young specialist (p < 0.001). Conclusion: 3D postoperative imaging reveals high incidences of CI misalignment. Application of a novel ultra-fast algorithm significantly reduces the time for diagnosis compared to MPR analysis for readers of varying experience levels. … (more)
- Is Part Of:
- European journal of radiology. Issue 151(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 151(2022)
- Issue Display:
- Volume 151, Issue 151 (2022)
- Year:
- 2022
- Volume:
- 151
- Issue:
- 151
- Issue Sort Value:
- 2022-0151-0151-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Cochlea -- Cochlea implant -- Artificial intelligence -- Automatic cochlear image registration -- Electrode misalignment
ACIR automatic cochlea implant registration -- CI cochlear implant -- MPR multiplanar reconstruction -- VRT volume rendering technique
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110283 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21539.xml