Seizure Detection in Continuous Inpatient EEG: A Comparison of Human vs Automated Review. (31st May 2022)
- Record Type:
- Journal Article
- Title:
- Seizure Detection in Continuous Inpatient EEG: A Comparison of Human vs Automated Review. (31st May 2022)
- Main Title:
- Seizure Detection in Continuous Inpatient EEG
- Authors:
- Ganguly, Taneeta Mindy
Ellis, Colin A.
Tu, Danni
Shinohara, Russell T.
Davis, Kathryn A.
Litt, Brian
Pathmanathan, Jay - Abstract:
- Abstract : Background and Objectives: The aim of this work was to test the accuracy of Persyst commercially available automated seizure detection in critical care EEG by comparing automated seizure detections to human review in a manually reviewed cohort and on a large scale. Methods: Automated seizure detections (Persyst versions 12 and 13) were compared to human review in a pilot cohort of 229 seizures from 85 EEG records and then in an expanded cohort of 7, 924 EEG records. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for individual seizures (pilot cohort) and for entire records (pilot and expanded cohorts). We assessed EEG features associated with the accuracy of automated seizure detections. Results: In the pilot cohort, accuracy of automated detection for individual seizures was modest (sensitivity 0.50, PPV 0.60). At the record level (did the recording contain seizures or not?), sensitivity was higher (pilot cohort 0.78, expanded cohort 0.91), PPV was low (pilot cohort 0.40, expanded cohort 0.08), and NPV was high (pilot cohort 0.88, expanded cohort 0.97). Different software versions (version 12 vs 13) performed similarly. Sensitivity was higher for records containing focal-onset seizures compared to generalized-onset seizures (0.93 vs 0.85, p = 0.012). Discussion: In critical care continuous EEG recordings, automated detection of individual seizures had rates of both false negatives and false positivesAbstract : Background and Objectives: The aim of this work was to test the accuracy of Persyst commercially available automated seizure detection in critical care EEG by comparing automated seizure detections to human review in a manually reviewed cohort and on a large scale. Methods: Automated seizure detections (Persyst versions 12 and 13) were compared to human review in a pilot cohort of 229 seizures from 85 EEG records and then in an expanded cohort of 7, 924 EEG records. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for individual seizures (pilot cohort) and for entire records (pilot and expanded cohorts). We assessed EEG features associated with the accuracy of automated seizure detections. Results: In the pilot cohort, accuracy of automated detection for individual seizures was modest (sensitivity 0.50, PPV 0.60). At the record level (did the recording contain seizures or not?), sensitivity was higher (pilot cohort 0.78, expanded cohort 0.91), PPV was low (pilot cohort 0.40, expanded cohort 0.08), and NPV was high (pilot cohort 0.88, expanded cohort 0.97). Different software versions (version 12 vs 13) performed similarly. Sensitivity was higher for records containing focal-onset seizures compared to generalized-onset seizures (0.93 vs 0.85, p = 0.012). Discussion: In critical care continuous EEG recordings, automated detection of individual seizures had rates of both false negatives and false positives that bring into question its utility as a seizure alarm in clinical practice. At the level of entire EEG records, the absence of automated detections accurately predicted EEG records without true seizures. The true value of Persyst automated seizure detection appears to lie in triaging of low-risk EEGs. Classification of Evidence: This study provides Class II evidence that an automated seizure detection program cannot accurately identify EEG records that contain seizures. … (more)
- Is Part Of:
- Neurology. Volume 98:Number 22(2022)
- Journal:
- Neurology
- Issue:
- Volume 98:Number 22(2022)
- Issue Display:
- Volume 98, Issue 22 (2022)
- Year:
- 2022
- Volume:
- 98
- Issue:
- 22
- Issue Sort Value:
- 2022-0098-0022-0000
- Page Start:
- e2224
- Page End:
- e2232
- Publication Date:
- 2022-05-31
- Subjects:
- Neurology -- Periodicals
Neurology -- Periodicals
Neurologie -- Périodiques
616.8 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=0028-3878 ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0nz0.html ↗
http://www.neurology.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1212/WNL.0000000000200267 ↗
- Languages:
- English
- ISSNs:
- 0028-3878
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21540.xml