Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study. (December 2020)
- Record Type:
- Journal Article
- Title:
- Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study. (December 2020)
- Main Title:
- Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve
- Authors:
- Forrestal, Brian J.
Case, Brian C.
Yerasi, Charan
Shea, Corey
Torguson, Rebecca
Zhang, Cheng
Ben-Dor, Itsik
Deksissa, Teshome
Ali, Syed
Satler, Lowell F.
Shults, Christian
Weissman, Gaby
Wang, John C.
Khan, Jaffar M.
Waksman, Ron
Rogers, Toby - Abstract:
- Abstract : Background: The supra-annular leaflet position and tall stent frame of the self-expanding Evolut PRO or Evolut PRO+ transcatheter heart valves (THVs) may cause coronary occlusion during transcatheter aortic valve replacement (TAVR)-in-TAVR and present challenges for future coronary access. We sought to evaluate the risk of TAVR-in-TAVR with Evolut PRO or Evolut PRO+ THVs and the feasibility of future coronary access. Methods: The CoreValve Evolut PRO Prospective Registry (EPROMPT; NCT03423459) prospectively enrolled patients with symptomatic severe aortic stenosis to undergo TAVR using a commercially available latest generation self-expanding THV at 2 centers in the United States. Computed tomography was performed 30 days after TAVR, which we used to simulate TAVR-in-TAVR with a second Evolut PRO or Evolut PRO+ THV and evaluate for risk of coronary obstruction and feasibility of future coronary access. Results: Eighty-one patients enrolled with interpretable computed tomography are reported herein. Computed tomography simulation predicted sinus of Valsalva sequestration and resultant coronary obstruction during future TAVR-in-TAVR in up to 23% of patients. Computed tomography simulation predicted that the position of the pinned THV leaflets would hinder future coronary access in up to 78% of patients after TAVR-in-TAVR. Conclusions: Further THV design improvements and leaflet modification strategies are needed to mitigate the risk of coronary obstruction duringAbstract : Background: The supra-annular leaflet position and tall stent frame of the self-expanding Evolut PRO or Evolut PRO+ transcatheter heart valves (THVs) may cause coronary occlusion during transcatheter aortic valve replacement (TAVR)-in-TAVR and present challenges for future coronary access. We sought to evaluate the risk of TAVR-in-TAVR with Evolut PRO or Evolut PRO+ THVs and the feasibility of future coronary access. Methods: The CoreValve Evolut PRO Prospective Registry (EPROMPT; NCT03423459) prospectively enrolled patients with symptomatic severe aortic stenosis to undergo TAVR using a commercially available latest generation self-expanding THV at 2 centers in the United States. Computed tomography was performed 30 days after TAVR, which we used to simulate TAVR-in-TAVR with a second Evolut PRO or Evolut PRO+ THV and evaluate for risk of coronary obstruction and feasibility of future coronary access. Results: Eighty-one patients enrolled with interpretable computed tomography are reported herein. Computed tomography simulation predicted sinus of Valsalva sequestration and resultant coronary obstruction during future TAVR-in-TAVR in up to 23% of patients. Computed tomography simulation predicted that the position of the pinned THV leaflets would hinder future coronary access in up to 78% of patients after TAVR-in-TAVR. Conclusions: Further THV design improvements and leaflet modification strategies are needed to mitigate the risk of coronary obstruction during TAVR-in-TAVR with self-expanding THVs and to facilitate future coronary access. Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03423459. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 13:Number 12(2020)
- Journal:
- Circulation
- Issue:
- Volume 13:Number 12(2020)
- Issue Display:
- Volume 13, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 13
- Issue:
- 12
- Issue Sort Value:
- 2020-0013-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- coronary obstruction -- heart valves -- transcatheter aortic valve replacement -- valve-in-valve
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.120.009496 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21506.xml