Incidence and Risk Factors for a Malpositioned Intrauterine Device Detected on Three‐Dimensional Ultrasound Within Eight Weeks of Placement. (27th September 2021)
- Record Type:
- Journal Article
- Title:
- Incidence and Risk Factors for a Malpositioned Intrauterine Device Detected on Three‐Dimensional Ultrasound Within Eight Weeks of Placement. (27th September 2021)
- Main Title:
- Incidence and Risk Factors for a Malpositioned Intrauterine Device Detected on Three‐Dimensional Ultrasound Within Eight Weeks of Placement
- Authors:
- Connolly, Courtney T.
Fox, Nathan S. - Abstract:
- Abstract : Objectives: To estimate the incidence of intrauterine device (IUD) malpositioning detected on three‐dimensional (3D) transvaginal ultrasound within 8 weeks of placement and identify risk factors for malpositioning. Methods: Retrospective study of women who had an IUD placed at a large obstetrics and gynecology practice from January 1, 2015, to December 31, 2020. All patients underwent two‐dimensional ultrasound at the time of insertion and routine three‐dimensional ultrasound within 8 weeks. Baseline characteristics and potential risk factors were compared between women with correctly positioned and malpositioned IUDs. Odds ratios were calculated by logistic regression to identify risk factors independently associated with malpositioning. Results: A total of 763 IUD placements were included, and 127 malpositioned IUDs were identified representing an overall rate of malpositioning of 16.6% (95% confidence interval [CI] 14.0–19.3) with 8.8% (95% CI 6.8–10.8) requiring removal. Patients with malpositioned IUD had higher rates of morbid obesity (13.4% versus 3.8%, adjusted odds ratio [aOR] 2.46, 95% CI 1.10–5.50), prior uterine window or rupture (9.0% versus 2.2%, aOR 2.78, 95% CI 1.06–7.30), copper IUD placement (64.2% versus 47.4%, aOR 1.99, 95% CI 1.31–3.03), and symptoms such as bleeding or pain at follow‐up (35.8% versus 20.1%, aOR 2.58, 95% CI 1.67–3.98). Parity, breastfeeding, difficult insertion, and uterine size and positioning were not significant.Abstract : Objectives: To estimate the incidence of intrauterine device (IUD) malpositioning detected on three‐dimensional (3D) transvaginal ultrasound within 8 weeks of placement and identify risk factors for malpositioning. Methods: Retrospective study of women who had an IUD placed at a large obstetrics and gynecology practice from January 1, 2015, to December 31, 2020. All patients underwent two‐dimensional ultrasound at the time of insertion and routine three‐dimensional ultrasound within 8 weeks. Baseline characteristics and potential risk factors were compared between women with correctly positioned and malpositioned IUDs. Odds ratios were calculated by logistic regression to identify risk factors independently associated with malpositioning. Results: A total of 763 IUD placements were included, and 127 malpositioned IUDs were identified representing an overall rate of malpositioning of 16.6% (95% confidence interval [CI] 14.0–19.3) with 8.8% (95% CI 6.8–10.8) requiring removal. Patients with malpositioned IUD had higher rates of morbid obesity (13.4% versus 3.8%, adjusted odds ratio [aOR] 2.46, 95% CI 1.10–5.50), prior uterine window or rupture (9.0% versus 2.2%, aOR 2.78, 95% CI 1.06–7.30), copper IUD placement (64.2% versus 47.4%, aOR 1.99, 95% CI 1.31–3.03), and symptoms such as bleeding or pain at follow‐up (35.8% versus 20.1%, aOR 2.58, 95% CI 1.67–3.98). Parity, breastfeeding, difficult insertion, and uterine size and positioning were not significant. Conclusions: The incidence of malpositioned IUD within 8 weeks of placement on 3D ultrasound is 16.6%, with 8.8% requiring removal. Significant risk factors for malpositioning include morbid obesity, prior uterine window or rupture, and copper IUD placement. These findings support the importance of routine follow‐up 3D ultrasound after seemingly successful IUD placement. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 41:Number 6(2022)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 41:Number 6(2022)
- Issue Display:
- Volume 41, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2022-0041-0006-0000
- Page Start:
- 1525
- Page End:
- 1536
- Publication Date:
- 2021-09-27
- Subjects:
- intrauterine device -- intrauterine device malposition -- long‐acting reversible contraception -- three‐dimensional ultrasound -- ultrasound
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.15836 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21485.xml