A biomechanical study of ligament tethers strengthening for the prevention of proximal junctional kyphosis after posterior long-segment spinal fusion. (April 2022)
- Record Type:
- Journal Article
- Title:
- A biomechanical study of ligament tethers strengthening for the prevention of proximal junctional kyphosis after posterior long-segment spinal fusion. (April 2022)
- Main Title:
- A biomechanical study of ligament tethers strengthening for the prevention of proximal junctional kyphosis after posterior long-segment spinal fusion
- Authors:
- Zhao, Gaiping
Wang, Xiaoyu
Liu, Dongqing
Wu, Kunneng
Zhao, Jian
Fei, Wang - Abstract:
- Abstract: Background: Proximal junctional kyphosis is a known complication of posterior long-segment thoracolumbar fusion. Here, the biomechanical effectiveness of ligament tethers strengthening and vertebral body augmentation, in proximal junctional kyphosis prevention was explored using the finite element analysis. Methods: Based on a validated model of T1-L5 with the pedicle screw system instrumented T8-L5, strengthening models with different strategies were created to assess the range of motion in proximal vertebrae, vertebrae stress, pedicle screw stress, and pressure on intervertebral discs during extension, flexion, lateral bending, and axial rotation motions. Strengthening strategies included two- and three-level posterior ligament tethers (TE-T7-T9 and TE-T6-T9), and tethers with T7 &T8 vertebral body augmentation (TECE-T7-T9 and TECE-T6-T9). Findings: Compared to the spinal fusion model, the ligament tethers strengthening significantly reduced the flexion-extension range of motion difference among the proximal vertebrae. During the flexion-extension motion, the T8 vertebra stresses in the TE-T7-T9, TE-T6-T9, TECE-T7-T9, and TECE-T6-T9 models were distinctively reduced, the values decreased by 26.8%, 28.3%, 28.8%, and 9.6%, respectively, during flexion, and by 21.9%, 35.2%, 23%, and 18.6%, respectively, during extension. In the strengthening models, the maximum stresses on the T7/T8 intervertebral disc in the TE-T6-T9 model were reduced by 13.8% during flexion andAbstract: Background: Proximal junctional kyphosis is a known complication of posterior long-segment thoracolumbar fusion. Here, the biomechanical effectiveness of ligament tethers strengthening and vertebral body augmentation, in proximal junctional kyphosis prevention was explored using the finite element analysis. Methods: Based on a validated model of T1-L5 with the pedicle screw system instrumented T8-L5, strengthening models with different strategies were created to assess the range of motion in proximal vertebrae, vertebrae stress, pedicle screw stress, and pressure on intervertebral discs during extension, flexion, lateral bending, and axial rotation motions. Strengthening strategies included two- and three-level posterior ligament tethers (TE-T7-T9 and TE-T6-T9), and tethers with T7 &T8 vertebral body augmentation (TECE-T7-T9 and TECE-T6-T9). Findings: Compared to the spinal fusion model, the ligament tethers strengthening significantly reduced the flexion-extension range of motion difference among the proximal vertebrae. During the flexion-extension motion, the T8 vertebra stresses in the TE-T7-T9, TE-T6-T9, TECE-T7-T9, and TECE-T6-T9 models were distinctively reduced, the values decreased by 26.8%, 28.3%, 28.8%, and 9.6%, respectively, during flexion, and by 21.9%, 35.2%, 23%, and 18.6%, respectively, during extension. In the strengthening models, the maximum stresses on the T7/T8 intervertebral disc in the TE-T6-T9 model were reduced by 13.8% during flexion and by 14.7% during extension. Interpretation: Based on our results, the ligament strengthening configuration of the three-level posterior tethers produced a more gradual transition in range of motion, vertebrae stresses, and intervertebral discs stress between the fused and non-fused segments, especially during flexion-extension, which may significantly decrease the proximal junctional kyphosis biomechanical risk. Highlights: Different ligament tethers strengthening models were developed. Ligament tethers may prevent proximal junctional kyphosis. Three-level posterior tethers achieve a better prevention effect. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 94(2022)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 94(2022)
- Issue Display:
- Volume 94, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 94
- Issue:
- 2022
- Issue Sort Value:
- 2022-0094-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-04
- Subjects:
- Proximal junction kyphosis -- Posterior thoracolumbar fusion -- Ligament tethers strengthening -- Finite element analysis
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2022.105621 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21447.xml