Feasibility of two‐dimensional dose distribution deconvolution using convolution neural networks. Issue 12 (6th November 2019)
- Record Type:
- Journal Article
- Title:
- Feasibility of two‐dimensional dose distribution deconvolution using convolution neural networks. Issue 12 (6th November 2019)
- Main Title:
- Feasibility of two‐dimensional dose distribution deconvolution using convolution neural networks
- Authors:
- Cheon, Wonjoong
Kim, Sung Jin
Kim, Kyuseok
Lee, Moonhee
Lee, Jinhyeop
Jo, Kwanghyun
Cho, Sungkoo
Cho, Hyosung
Han, Youngyih - Abstract:
- Abstract : Purpose: The purpose of this study was to investigate the feasibility of two‐dimensional (2D) dose distribution deconvolution using convolutional neural networks (CNNs) instead of an analytical approach for an in‐house scintillation detector that has a detector‐interface artifact in the penumbra region. Methods: Datasets of 2D dose distributions were acquired from a medical linear accelerator of Novalis Tx. The datasets comprise two different sizes of square radiation fields and 13 clinical intensity‐modulated radiation treatment (IMRT) plans. These datasets were divided into two datasets (training and test) to train and validate the developed network, called PenumbraNet, which is a shallow linear CNN. The PenumbraNet was trained to transform the measured dose distribution [M(x, y)] to calculated distribution [D(x, y)] by the treatment planning system. After training of the PenumbraNet was completed, the performance was evaluated using test data, which were 10 × 10 cm 2 open field and ten clinical IMRT cases. The corrected dose distribution [C(x, y)] was evaluated against D(x, y) with 2%/2 mm and 3%/3 mm criteria of the gamma index for each field. The M(x, y) and deconvolved dose distribution with the analytically obtained kernel using Wiener filtering [A(x, y)] were also evaluated for comparison. In addition, we compared the performance of the shallow depth of linear PenumbraNet with that of nonlinear PenumbraNet and a deep nonlinear PenumbraNet within the sameAbstract : Purpose: The purpose of this study was to investigate the feasibility of two‐dimensional (2D) dose distribution deconvolution using convolutional neural networks (CNNs) instead of an analytical approach for an in‐house scintillation detector that has a detector‐interface artifact in the penumbra region. Methods: Datasets of 2D dose distributions were acquired from a medical linear accelerator of Novalis Tx. The datasets comprise two different sizes of square radiation fields and 13 clinical intensity‐modulated radiation treatment (IMRT) plans. These datasets were divided into two datasets (training and test) to train and validate the developed network, called PenumbraNet, which is a shallow linear CNN. The PenumbraNet was trained to transform the measured dose distribution [M(x, y)] to calculated distribution [D(x, y)] by the treatment planning system. After training of the PenumbraNet was completed, the performance was evaluated using test data, which were 10 × 10 cm 2 open field and ten clinical IMRT cases. The corrected dose distribution [C(x, y)] was evaluated against D(x, y) with 2%/2 mm and 3%/3 mm criteria of the gamma index for each field. The M(x, y) and deconvolved dose distribution with the analytically obtained kernel using Wiener filtering [A(x, y)] were also evaluated for comparison. In addition, we compared the performance of the shallow depth of linear PenumbraNet with that of nonlinear PenumbraNet and a deep nonlinear PenumbraNet within the same training epoch. Results: The mean gamma passing rates were 84.77% and 95.81% with 3%/3 mm gamma criteria for A(x, y) and C(x, y) of the PenumbraNet, respectively. The mean gamma pass rates of nonlinear PenumbraNet and the deep depth of nonlinear PenumbraNet were 96.62%, 93.42% with 3%/3 mm gamma criteria, respectively. Conclusions: We demonstrated the feasibility of the PenumbraNets for 2D dose distribution deconvolution. The nonlinear PenumbraNet which has the best performance improved the gamma passing rate by 11.85% from the M(x, y) at 3%/3 mm gamma criteria. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 12(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 12(2019)
- Issue Display:
- Volume 46, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 12
- Issue Sort Value:
- 2019-0046-0012-0000
- Page Start:
- 5833
- Page End:
- 5847
- Publication Date:
- 2019-11-06
- Subjects:
- convolution neural network -- deconvolution -- scintillation detector
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13869 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21423.xml