Head and neck squamous cell carcinoma: evaluation of iodine overlay maps and low-energy virtual mono-energetic images acquired with spectral detector CT. Issue 6 (June 2022)
- Record Type:
- Journal Article
- Title:
- Head and neck squamous cell carcinoma: evaluation of iodine overlay maps and low-energy virtual mono-energetic images acquired with spectral detector CT. Issue 6 (June 2022)
- Main Title:
- Head and neck squamous cell carcinoma: evaluation of iodine overlay maps and low-energy virtual mono-energetic images acquired with spectral detector CT
- Authors:
- Zopfs, D.
Lennartz, S.
Große Hokamp, N.
Rau, K.
Zaeske, C.
Laukamp, K.R.
Houbois, C.
Luers, J.C.
Maintz, D.
Puesken, M. - Abstract:
- Abstract : AIM: To evaluate the diagnostic value of spectral detector computed tomography (SDCT)-derived iodine overlay maps and low-energy virtual mono-energetic images (VMI) for the initial locoregional assessment of primary, therapy-naive head and neck cancer. MATERIALS AND METHODS: Fifty-six patients with histologically confirmed untreated squamous cell carcinoma of the head and neck who underwent SDCT of the neck for staging purposes were included in this retrospective study. Attenuation, image noise as well as signal- and contrast-to-noise ratios (S-/CNR) in VMI40–70keV were obtained from region of interest (ROI)-based measurements in the tumour and important anatomical landmarks (sternocleidomastoid muscle, subcutaneous fat, thyroid gland, submandibular gland, carotid artery, and jugular vein). Tumour conspicuity and delineation, as well as subjective image quality, were rated for conventional images, VMI40–70keV, and iodine overlay maps using five-point Likert scales. RESULTS: The CNR of the tumour versus the floor of the mouth and the CNR of the tumour versus the sternocleidomastoid muscle was significantly higher in VMI40keV in comparison to conventional images (10.0 ± 7.3 versus 3.8 ± 3.3 and 11.3 ± 7.6 versus 3.6 ± 2.8; p< 0.05 each). This was supported by qualitative results, as tumour conspicuity and delineation received superior ratings in iodine overlay maps and VMI40keV compared to conventional images (5 [3–5] and 5 [4–5] versus 3 [2–5]; 5 [2–5] and 5 [3–5]Abstract : AIM: To evaluate the diagnostic value of spectral detector computed tomography (SDCT)-derived iodine overlay maps and low-energy virtual mono-energetic images (VMI) for the initial locoregional assessment of primary, therapy-naive head and neck cancer. MATERIALS AND METHODS: Fifty-six patients with histologically confirmed untreated squamous cell carcinoma of the head and neck who underwent SDCT of the neck for staging purposes were included in this retrospective study. Attenuation, image noise as well as signal- and contrast-to-noise ratios (S-/CNR) in VMI40–70keV were obtained from region of interest (ROI)-based measurements in the tumour and important anatomical landmarks (sternocleidomastoid muscle, subcutaneous fat, thyroid gland, submandibular gland, carotid artery, and jugular vein). Tumour conspicuity and delineation, as well as subjective image quality, were rated for conventional images, VMI40–70keV, and iodine overlay maps using five-point Likert scales. RESULTS: The CNR of the tumour versus the floor of the mouth and the CNR of the tumour versus the sternocleidomastoid muscle was significantly higher in VMI40keV in comparison to conventional images (10.0 ± 7.3 versus 3.8 ± 3.3 and 11.3 ± 7.6 versus 3.6 ± 2.8; p< 0.05 each). This was supported by qualitative results, as tumour conspicuity and delineation received superior ratings in iodine overlay maps and VMI40keV compared to conventional images (5 [3–5] and 5 [4–5] versus 3 [2–5]; 5 [2–5] and 5 [3–5] versus 3 [2–4], respectively, all p< 0.05). VMI40keV yielded the highest score among all included image reconstructions for overall image quality ( p< 0.05 all). CONCLUSION: Iodine overlay maps and low-energy VMI derived from SDCT improve initial assessment of primary squamous cell carcinoma of the head and neck compared to conventional images. Highlights: Low-keV VMI improve objective image parameters in the assessment of HNC. Iodine overlay maps and low-keV VMI significantly improve tumour delineation. Assessment of relevant anatomical structures profited from using low-keV VMI. … (more)
- Is Part Of:
- Clinical radiology. Volume 77:Issue 6(2022)
- Journal:
- Clinical radiology
- Issue:
- Volume 77:Issue 6(2022)
- Issue Display:
- Volume 77, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 77
- Issue:
- 6
- Issue Sort Value:
- 2022-0077-0006-0000
- Page Start:
- e425
- Page End:
- e433
- Publication Date:
- 2022-06
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2022.02.013 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21410.xml