Effects of three food-simulating liquids on the roughness and hardness of CAD/CAM polymer composites. Issue 5 (May 2022)
- Record Type:
- Journal Article
- Title:
- Effects of three food-simulating liquids on the roughness and hardness of CAD/CAM polymer composites. Issue 5 (May 2022)
- Main Title:
- Effects of three food-simulating liquids on the roughness and hardness of CAD/CAM polymer composites
- Authors:
- Babaier, Rua
Watts, David C.
Silikas, Nick - Abstract:
- Abstract: Objective: Implant-supported frameworks constructed from high-performance polymer CAD/CAM composites are exposed to liquids from the oral environment and routine care maintenance. Therefore, this study investigated the effect of food-simulating liquids (FSLs) on surface properties of three CAD/CAM polymer composite blocks. Methods: The composites investigated were (i) a carbon fibre-reinforced composite (CarboCAD 3D dream frame; CC), (ii) a glass fibre-reinforced composite (TRINIA; TR), and (iii) a reinforced PEEK (DentoKeep; PK). The filler contents were determined by thermo-gravimetry. The surface properties were roughness, Vickers hardness (HV), properties measured by Martens force/depth indentation, namely: hardness (HM), modulus (E IT ) and creep (C IT ). Property measurements were made at baseline on polished specimens and then, where possible, after 1- and 7-days storage at 37 ℃ in three different media: water, 70% ethanol/water and MEK (methyl ethyl ketone). Specimens were selected for light and scanning electron microscopy. Statistical analysis was performed by two-way repeated measures ANOVA, one-way ANOVA, and multiple comparison tests (α = 0.05). Results: The baseline roughness and hardness (HV, HM) and modulus (E IT ) correlated approximately with filler content (wt%), with the fibre-reinforced composites being rougher, harder and stiffer than PK. At baseline, roughness (Sa) ranged from 0.202 to 0.268 µm; HV from 23.1 to 36.9; HM from 224.5 toAbstract: Objective: Implant-supported frameworks constructed from high-performance polymer CAD/CAM composites are exposed to liquids from the oral environment and routine care maintenance. Therefore, this study investigated the effect of food-simulating liquids (FSLs) on surface properties of three CAD/CAM polymer composite blocks. Methods: The composites investigated were (i) a carbon fibre-reinforced composite (CarboCAD 3D dream frame; CC), (ii) a glass fibre-reinforced composite (TRINIA; TR), and (iii) a reinforced PEEK (DentoKeep; PK). The filler contents were determined by thermo-gravimetry. The surface properties were roughness, Vickers hardness (HV), properties measured by Martens force/depth indentation, namely: hardness (HM), modulus (E IT ) and creep (C IT ). Property measurements were made at baseline on polished specimens and then, where possible, after 1- and 7-days storage at 37 ℃ in three different media: water, 70% ethanol/water and MEK (methyl ethyl ketone). Specimens were selected for light and scanning electron microscopy. Statistical analysis was performed by two-way repeated measures ANOVA, one-way ANOVA, and multiple comparison tests (α = 0.05). Results: The baseline roughness and hardness (HV, HM) and modulus (E IT ) correlated approximately with filler content (wt%), with the fibre-reinforced composites being rougher, harder and stiffer than PK. At baseline, roughness (Sa) ranged from 0.202 to 0.268 µm; HV from 23.1 to 36.9; HM from 224.5 to 330.6 N/mm 2 ; E IT : from 6 to 9.8 GPa. After ageing in 70% ethanol and MEK, more pronounced roughness and hardness changes were observed than in water. MEK caused greater deterioration for the FRC than 70% ethanol, while PK specimens showed slight changes in 70% ethanol. Significance: Storage media adversely affected the surface and mechanical properties of each CAD/CAM composite. However, during ageing, the reinforced PEEK showed greater relative stability in these properties. Nevertheless, the deterioration may indicate the need for full protection by a veneer material on each surface of an implant-supported framework. … (more)
- Is Part Of:
- Dental materials. Volume 38:Issue 5(2022)
- Journal:
- Dental materials
- Issue:
- Volume 38:Issue 5(2022)
- Issue Display:
- Volume 38, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2022-0038-0005-0000
- Page Start:
- 874
- Page End:
- 885
- Publication Date:
- 2022-05
- Subjects:
- CAD/CAM composites -- Food-simulating liquid -- Ageing -- Surface roughness -- Vickers hardness -- Martens hardness
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2022.04.001 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21378.xml